Parameter
Nom.Cross-section Area | overall diameter | cable Weight | DC Resistance at 20℃ Conductor min | Current Carrying Capacity at 30℃ | |
In Air | In Ground | ||||
mm² | mm | km/kg | Ω/km | A | A |
3×35 | 50.0 | 4355 | 0.524 | 172 | 154 |
3×50 | 53.0 | 5095 | 0.387 | 205 | 181 |
3×70 | 57.5 | 6045 | 0.268 | 253 | 220 |
3×95 | 61.5 | 7165 | 0.193 | 307 | 263 |
3×120 | 65.0 | 8105 | 0.153 | 352 | 298 |
3×150 | 68.0 | 9645 | 0.124 | 397 | 332 |
3× 185 | 72.0 | 11055 | 0.0991 | 453 | 374 |
3×240 | 77.0 | 13165 | 0.0754 | 529 | 431 |
3×300 | 84.5 | 15700 | 0.0601 | 599 | 482 |
N2XSEYFGbY 3.6/6kV
Nom.Cross-section Area | overall diameter | cable Weight | DC Resistance at 20℃ Conductor min | Current Carrying Capacity at 30℃ | |
In Air | In Ground | ||||
mm² | mm | km/kg | Ω/km | A | A |
3×35 | 54.5 | 4860 | 0.524 | 172 | 154 |
3×50 | 58.0 | 5650 | 0.387 | 205 | 181 |
3×70 | 62.5 | 6670 | 0.268 | 253 | 220 |
3×95 | 66.0 | 7795 | 0.193 | 307 | 263 |
3×120 | 69.5 | 8765 | 0.153 | 352 | 298 |
3×150 | 73.0 | 10330 | 0.124 | 397 | 332 |
3× 185 | 76.5 | 11775 | 0.0991 | 453 | 374 |
3×240 | 81.5 | 13855 | 0.0754 | 529 | 431 |
3×300 | 88.0 | 16295 | 0.0601 | 599 | 482 |
N2XSEYFGbY 6/10kV
Nom.Cross-section Area | overall diameter | cable Weight | DC Resistance at 20℃ Conductor min | Current Carrying Capacity at 30℃ | |
In Air | In Ground | ||||
mm² | mm | km/kg | Ω/km | A | A |
3×35 | 60.5 | 5570 | 0.524 | 172 | 154 |
3×50 | 63.5 | 6.365 | 0.387 | 205 | 181 |
3×70 | 67.5 | 7395 | 0.268 | 253 | 220 |
3×95 | 71.5 | 8555 | 0.193 | 307 | 263 |
3×120 | 75.0 | 9600 | 0.153 | 352 | 298 |
3×150 | 78.5 | 11195 | 0.124 | 397 | 332 |
3× 185 | 82.0 | 12680 | 0.0991 | 453 | 374 |
3×240 | 87.0 | 14815 | 0.0754 | 529 | 431 |
3×300 | 93.5 | 17320 | 0.0601 | 599 | 482 |
N2XSEYFGbY 8.7/15kV
Nom.Cross-section Area | overall diameter | cable Weight | DC Resistance at 20℃ Conductor min | Current Carrying Capacity at 30℃ | |
In Air | In Ground | ||||
mm² | mm | km/kg | Ω/km | A | A |
3×35 | 65.5 | 6215 | 0.524 | 172 | 154 |
3×50 | 68.5 | 7070 | 0.387 | 205 | 181 |
3×70 | 73 | 8145 | 0.268 | 253 | 220 |
3×95 | 76.5 | 9310 | 0.193 | 307 | 263 |
3×120 | 80 | 10385 | 0.153 | 352 | 298 |
3×150 | 83.5 | 12050 | 0.124 | 397 | 332 |
3× 185 | 87 | 13525 | 0.0991 | 453 | 374 |
3×240 | 92 | 15700 | 0.0754 | 529 | 431 |
3×300 | 98.5 | 18220 | 0.0601 | 599 | 482 |
N2XSEYFGbY 12/20kV
Cable Structure
● Conductor:Compact stranded copper conductor,CI.2 as per IEC 60228
Conductor Screen: Semi-ductor
● Insulation:XLPE rated at 90°C
● Conducting Water Blocking Layer:Semi-conductive WBT
● ID Tape:Red/Yellow/Black
● Metallic Screen:Copper Tape Screen
● Metallic Screen:Copper Tape Screen
● Separator/Water Blocking Layer:Non-Conductive WBT
● Separation Sheath(for armoured cable):PVC inner Sheath(Fully extruded)
● Armoring:Galvanized Steel Flat Armor
Galvanized Steel Tape
●Sheath:PVC or FR-PVC type ST2/ST8 to IEC 60502,black
Code Designatio
YJ:XLPE velit
V:PVC vaginam
22: Duplex galvanized chalybeum filum armatura-3 coros
62: Duplex immaculata ferro taenia armoring-1 core
ZR: Flamma repugnans
European Union:N2XSEYFGbY
Applicationem
They are suitable for installation mostly in power supply stations, indoors and in cable ducts,outdoors,underground and in water as well as for installation on cable trays for industries,switchboards and power stations.
Standard
International:IEC 60502,EC60228,(IEC60332-3forZR-YJV22,ZR-YJV62only)
China:GB/T12706,(GB/T18380-3forZR-YJV22,ZR-YJV62only)
European standard:DIN VDE0276-620,HD620S2,IEC/EN 60228,IEC/EN 60502-2
Flame Retardant according to IEC/EN 60332-1-2
Indonesian Standard:Conductor:SNI IEC 60228/Insulation:SNI IEC 60502-2
Alia signa ut BS, DIN et ICEA postulantibus
Technical data
Rated voltage:3.6/6KV 6/10KV 8.7/15KV 12/20KV
Maximum Conductor Temperature: sub normalibus (90℃), subitis (130℃) vel ambitus brevis non plus quam 5s (250℃) condicionibus.
Min.Ambient Temp.-20°℃,Installation Temp.0℃
Min.Bending Badius: 15×cable OD pro uno core
12×cable OD for multi core
Testimonia
CE, RoHS, CCC, KEMA, et plures alii ad petitionem