N2XSEFGbY/NA2XSEFGbY 3.6/6kV 6/10kV 8.7/15kV 12/20kV 18/30kV MEDIUM VOLTAGE Cu(AL) CONDUCTOR XLPE INSULATED MULTI-CORE STEEL TAPE ARMOURED POWER CABLE

Model Number:N2XSEFGbY/NA2XSEFGbYCu(AI)/XLPE/CTS/PVC/SFWA/PVC,  3.6/6kV 6/10kV 8.7/15kV 12/20kV 18/30kV
Kategorie: Energie Kabelen / Power Kabelen / Industriell Kabel
Plaz vun Urspronk: XingTai, China
Markennumm: TIANHUAN
Certification ISO,CE,IEC,TUV

Minimum order quantity:5000 meters





DOWNLOAD PDF
Detailer
Tags

Parameter

Nom.Cross-section Area overall diameter cable Weight DC Resistance at 20℃ Conductor min Current Carrying Capacity at 30℃
In Air In Ground
mm² mm km/kg Ω/km A A
3x25 38.5 2603 0.727 152 147
3x35 41.5 3074 0.524 185 175
3 x50 44.5 3641 0.387 219 205
3 x70 48.5 4536 0.268 273 251
3 x95 52 5542 0.193 330 299
3x120 56 6516 0.153 379 339
3x150 59.5 7593 0.124 430 379
3x185 63 8940 0.0991 490 427
3x240 69 11074 0.0754 573 490
3x300 75.5 13395 0.0601 649 547

                                 N2XSEFGbY 3.6/6kV

 

Nom.Cross-section Area overall diameter cable Weight DC Resistance at 20℃ Conductor min Current Carrying Capacity at 30℃
In Air In Ground
mm² mm km/kg Ω/km A A
3x25 43 2984 0.727 155 147
3x35 46 3515 0.524 187 175
3 x50 48.5 4061 0.387 222 205
3 x70 52.5 4955 0.268 276 251
3 x95 56.5 6055 0.193 333 298
3x120 60 7026 0.153 382 339
3x150 63.5 8110 0.124 433 379
3x185 67.5 9478 0.0991 493 426
3x240 73.5 11663 0.0754 574 489
3x300 78.5 13814 0.0601 650 546

                                    N2XSEFGbY 6/10kV

 

Nom.Cross-section Area overall diameter cable Weight DC Resistance at 20℃ Conductor min Current Carrying Capacity at 30℃
In Air In Ground
mm² mm km/kg Ω/km A A
3x25 49 3552 0.727 156 146
3x35 51.5 4072 0.524 189 174
3 x50 54 4606 0.387 225 205
3 x70 58.5 5619 0.268 278 250
3 x95 62 6697 0.193 336 298
3x120 65.5 7705 0.153 385 338
3x150 69 8810 0.124 435 378
3x185 73 10284 0.0991 494 424
3x240 79 12429 0.0754 577 488
3x300 83.5 14586 0.0601 654 547

                                        N2XSEFGbY 8.7/15kV

 

Nom.Cross-section Area overall diameter cable Weight DC Resistance at 20℃ Conductor min Current Carrying Capacity at 30℃
In Air In Ground
mm² mm km/kg Ω/km A A
3x35 56.5 4624 0.524 190 174
3 x50 59 5185 0.387 226 205
3 x70 63 6194 0.268 280 250
3 x95 66.5 7276 0.193 338 298
3x120 70 8318 0.153 387 338
3x150 74 9516 0.124 437 377
3x185 78 10981 0.0991 496 424
3x240 83.5 13130 0.0754 579 488
3x300 88.5 15374 0.0601 655 546

                                     N2XSEFGbY 12/20kV                                       

 

Nom.Cross-section Area overall diameter cable Weight DC Resistance at 20℃ Conductor min Current Carrying Capacity at 30℃
In Air In Ground
mm² mm km/kg Ω/km A A
3 x50 71 6738 0.387 229 204
3 x70 75.5 7869 0.268 282 249
3 x95 79 9021 0.193 340 296
3x120 82.5 10109 0.153 389 336
3x150 86 11335 0.124 440 376
3x185 90 12808 0.0991 500 423
3x240 95.5 15124 0.0754 582 487
3x300 101 17512 0.0601 657 545

                                  N2XSEFGbY 18/30kV                                  

Kabel Struktur

● Conductor:Compact stranded copper conductor,CI.2 as per IEC 60228

● Dirigent Écran: Semi-Dirigent

● Insulation:XLPE rated at 90°C

● ID Tape:Red/Yellow/Black

● Metallic Screen:Copper Tape Screen

● ID Tape:Red/Yellow/Black

● Separation Sheath(for armoured cable):PVC inner Sheath(Fully extruded)

● Armoring:Galvanized Steel Flat Armor

              Galvanized Steel Tape

●Sheath:PVC or FR-PVC type ST2/ST8 to IEC 60502,black

Code Bezeechnung

YJ: XLPE Isolatioun

V: PVC Mantel

22: Duebel galvaniséierte Stahldraht Armoring-3 Kären

62: Duebel Edelstahl Band Armoring-1 Kär

ZR: Flammbeständeg

European Union:N2XSEFGbY/NA2XSEFGbY

Applikatioun

For installation in the ground, indoors,cable trunking and outdoors if increased mechanical protection is required or where high-pulling stresses may occur during installation or operation.

Standard

International:IEC 60502,EC60228,(IEC60332-3forZR-YJV22,ZR-YJV62only)

China:GB/T12706,(GB/T18380-3forZR-YJV22,ZR-YJV62only)

European standard:DIN VDE0276-620,HD620S2,IEC/EN 60228,IEC/EN 60502-2

                            Flame Retardant according to IEC/EN 60332-1-2

Indonesian Standard:Conductor:SNI IEC 60228/Insulation:SNI IEC 60502-2

Aner Standarde wéi BS, DIN an ICEA op Ufro

Technesch Donnéeën

Rated voltage:3.6/6KV6/10KV 8.7/15KV 12/20KV 18/30kV

Maximal Dirigenttemperatur: ënner normalen (90 ℃), Noutfall (130 ℃) oder Kuerzschluss net méi wéi 5s (250 ℃) Konditiounen.

Min.Ambient Temp.-20°℃,Installation Temp.0℃

Min.Béie Radius: 15 × Kabel OD fir eenzel Kär 

                             12 × Kabel OD fir Multi Kär

Certificaten

CE, RoHS, CCC, KEMA a méi anerer op Ufro

Wann Dir un eise Produkter interesséiert sidd, kënnt Dir wielen Är Informatioun hei ze verloossen, a mir wäerte kuerz mat Iech a Kontakt sinn.


Schreift Äre Message hei a schéckt en un eis

Wann Dir un eise Produkter interesséiert sidd, kënnt Dir wielen Är Informatioun hei ze verloossen, a mir wäerte kuerz mat Iech a Kontakt sinn.