NYRGBY 0.6/1kv Cu conductors PVC insulated Galvanized Flar Steel Wire Armor and PVC sheathed power cable

Power cable 0.6/1kV with Copper conductors,PVC  insulated, Galvanized Flar Steel Wire Armor, PVC sheathed

Model Number:Cu/PVC/SWA/PVC,0.6/1kV(NYFGBY)
Category: Energy Cables/Power Cables/Industrial Cable
Place of Origin: XingTai, China
Brand Name: TIANHUAN
Certification ISO,CE,IEC,TUV

Minimum order quantity: 5000 meters





DOWNLOAD PDF
Details
Tags

Parameter

Nom.Cross-section Area Nominal Thickness overall diameter cable Weight DC Resistance at 20℃Insulation min Current Carrying Capacity at 30℃
Insulation Outer Sheath In Air In Ground
mm² mm² mm mm km/kg M.Ω.km mm mm
2 × 1.5 re 0.8 1.8 13.9 374 12 27 21
2 × 1.5 rm 0.8 1.8 14.3 375 11 27 21
2 × 2.5 re 0.8 1.8 14.6 406 10 36 29
2 × 2.5 rm 0.8 1.8 15.2 430 9 36 29
2 × 4 re 1.0 1.8 16.4 503 10 47 38
2 × 4 rrn 1.0 1.8 17 536 9 47 38
2 × 6 re 1.0 1.8 18 674 9 59 48
2 × 6 rm 1.0 1.8 18.9 734 8 59 48
2 × 10 re 1.0 1.8 20.1 781 7 78 66
2 × 10 rm 1.0 1.8 20.8 908 6 78 66
2 × 16 rm 1.0 1.8 23.4 1296 5 102 90
2 × 25 rm 1.2 1.8 26.6 1688 5 134 120
2 × 35 rm 1.2 1.8 28.9 2030 4 160 150
2 × 50 rm 1.4 1.9 33.6 2812 4 187 180
2 × 70 rm 1.4 2.0 36.8 3430 4 230 230
2 × 95 rm 1.6 2.1 42.2 4470 4 280 275
2 × 120 rm 1.6 2.2 46.5 5648 3 320 320
2 × 150 rm 1.8 2.3 50.6 6650 3 355 375
2 × 185 rm 2.0 2.5 55.8 8007 3 409 430
2 × 240 rm 2.2 2.7 62.2 9952 3 472 510
2 × 300 rm 2.4 2.8 58.5 11918 3 525 590
3 × 1.5 re 0.8 1.8 14.3 390 12 24 18
3 × 1.5 rm 0.8 1.8 14.8 410 11 24 18
3 × 2.5 re 0.8 1.8 15.2 451 10 32 25
3 × 2.5 rm 0.8 1.8 15.8 479 9 32 25
3 × 4 re 1.0 1.8 17.8 655 10 41 34
3 × 4 rm 1.0 1.8 18.5 699 9 41 34
3 × 6 re 1.0 1.8 18.8 762 9 52 44
3 × 6 rm 1.0 1.8 19.7 819 8 52 44
3 × 10 re 1.0 1.8 21.1 1025 7 69 60
3 × 10 rm 1.0 1.8 21.8 1044 6 69 60
3 × 16 rm 1.0 1.8 24.5 1416 5 89 80
3 × 25 rm 1.2 1.8 28.1 1894 5 116 105
3 × 35 rm 1.2 1.8 30.5 2321 4 138 130
3 × 50 sm 1.4 1.9 32.7 2784 4 165 160
3 × 70 sm 1.4 2.0 36.7 3806 4 205 200
3 × 95 sm 1.6 2.2 41 4882 4 245 245
3 × 120 sm 1.6 2.3 43.7 5853 3 285 285
3 × 150 sm 1.8 2.4 48.9 7407 3 315 325
3 × 185 sm 2.0 2.6 52.5 8774 3 355 370
3 × 240 sm 2.2 2.8 57.9 11036 3 415 435
3 × 300 sm 2.4 3.0 62.5 13137 3 465 500
4 × 1.5 re 0.8 1.8 15.2 433 12 24 18
4 × 1.5 rm 0.8 1.8 15.6 455 11 24 18
4 × 2.5 re 0.8 1.8 16 515 10 32 25
4 × 2.5 rm 0.8 1.8 16.7 538 9 32 25
4 × 4 re 1.0 1.8 18.8 740 10 41 34
4 × 4 rm 1.0 1.8 19.7 790 9 41 34
4 × 6 re 1.0 1.8 20.8 870 9 52 44
4 × 6 rm 1.0 1.8 21 925 8 52 44
4 × 10 re 1.0 1.8 23.6 1298 7 69 60
4 × 10 rm 1.0 1.8 24 1317 6 69 60
4 × 16 rm 1.0 1.8 26.3 1548 5 89 80
4 × 25 rm 1.2 1.8 30.4 2241 5 116 105
4 × 35 rm 1.2 1.9 32.9 2933 4 138 130
4 × 50 sm 1.4 2.0 33.9 2934 4 165 160
4 × 70 sm 1.4 2.1 38.7 4148 4 205 200
4 × 95 sm 1.6 2.3 43.9 5489 4 245 245
4 × 120 sm 1.6 2.4 48.2 7163 3 285 285
4 × 150 sm 1.8 2.6 52.5 8637 3 315 325
4 × 185 sm 2.0 2.8 57.2 10354 3 355 370
4 × 240 sm 2.2 3.0 64.3 13347 3 415 435
4 × 300 sm 2.4 3.2 72.5 16702 3 465 500
5 × 1.5 re 0.8 1.8 16 484 12 24 18
5 × 1.5 rm 0.8 1.8 16.5 509 11 24 18
5 × 2.5 re 0.8 1.8 17.7 647 10 32 25
5 × 2.5 rm 0.8 1.8 18.5 687 9 32 25
5 × 4 re 1.0 1.8 20 839 10 41 34
5 × 4 rm 1.0 1.8 21 897 9 41 34
5 × 6 re 1.0 1.8 21.4 996 9 52 44
5 × 6 rm 1.0 1.8 22.5 1069 8 52 44
5 × 10 re 1.0 1.8 25 1502 7 69 60
5 × 10 rm 1.0 1.8 25.7 1527 6 69 60
5 × 16 rm 1.0 1.8 28.3 1928 5 89 80
5 × 25 rm 1.2 1.9 33.2 2641 5 116 105
5 × 35 rm 1.2 2.0 37.4 3520 4 138 130
5 × 50 rm 1.4 2.1 43 4921 4 165 160

Cable Structure

● Conductor: [re] round solid conductor

                    [rm] circular stranded conductor

                    [Sm]Sector shape conductor

● Insulation: XLPE

● Filler:PVC

● Armour:A layers of Galvanized flat steel wires 4×0.8 mm with a counter helix layer of galvanized steel tape

● Out Sheath: PVC or FR-PVC type ST1/ST2/ST8,black

Code Designation

NYRGBY

Application

For general purpose distribution in dry or wet location,best suitable for direct burying in ground.

Standard

European standards:IEC 60502-1,VDE 0271,IS 1516.1

                              Flame retardant according to EN 60332-1

Indonesia standards:Conductor SNI IEC 60228/PVC insulation SNI IEC 60502-1/

                             PVC Sheath grade ST1 to SNI IEC 60502-1

Technical Data

Rated voltage:U0/U 0.6/1 kV

Test Voltage:3.5kV

Temperature Rating Maximum Operating: +70℃

                             Maximum Short-Circuit:+160℃

Minimum. Bend Radius:12×overall diameter

Certificates

CE, RoHS,CCC, KEMA and more others at request

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us