N2XSEY/NA2XSEY MEDIUM VOLTAGE Cu/AL conductor XLPE INSULATED UNARMORED POWER CABLE

Non Armoured cable with multi cores of copper conductors, XLPE insulation, Semi-conductor screen, Copper tape screen, Low Smoke Zero Halogen (LSZH) outer sheath or PVC sheath. Gives Rated voltage 3.6/6 KV,6/10kV,8.7/15kV,12/20kV,18/30kV,21/35kV,26/35kV for indoor and outdoor installation, in air and ground

Model Number: N2XSEY/NA2XSEY(CU(AL)/XLPE/CTS/PVC-AL/XLPE/CTS/PVC),3.6/6 KV,6/10kV,8.7/15kV,12/20kV,18/30kV,21/35kV,26/35kV
Category: Energy Cables/Power Cables/Industrial Cable
Place of Origin: XingTai, China
Brand Name: TIANHUAN
Certification ISO,CE,IEC,TUV

Minimum order quantity:5000 meters





DOWNLOAD PDF
Details
Tags

Parameter

Nom.Cross-
section of
conductor
Insulation
Thickness
Sheath
Thickness
Approx O.D. Approx
Weight
Max.D.C.Resistance of Conductor
(20℃)
Test Voltage   A.C Current Rating
mm² mm mm mm kg/km Ω/km kV/5min In air (A) In soil(A)
1×25 2.5 1.5 18 619 0.727 12.5 135 150
1×35 2.5 1.5 19 737 0.524 12.5 165 180
1×50 2.5 1.6 20 901 0.387 12.5 200 215
1×70 2.5 1.6 22 1128 0.268 12.5 250 265
1×95 2.5 1.7 23 1391 0. 193 12.5 305 315
1×120 2.5 1.8 25 1655 0. 153 12.5 355 360
1×150 2.5 1.8 26 1961 0. 124 12.5 405 405
1×185 2.5 1.9 28 2334 0.0991 12.5 465 455
1×240 2.6 1.9 30 2904 0.0754 12.5 550 530
1×300 2.8 2 33 3547 0.0601 12.5 635 595
1×400 3 2.2 37 4572 0.047 12.5 745 680
1×500 3.2 2.3 41 5630 0.0366 12.5 855 765
1×630 3.2 2.4 45 6922 0.0283 12.5 980 860
1×800 3.2 2.5 50 8252 0.0221 12.5 1130 950
1×1000 3.2 2.6 54.8 10548 0.0176 12.5 1240 1040
3×25 2.5 2.1 37 1858 0.727 12.5 120 125
3×35 2.5 2.2 39 2244 0.524 12.5 145 155
3×50 2.5 2.3 40 2767 0.387 12.5 175 180
3×70 2.5 2.4 45 3494 0.268 12.5 215 220
3×95 2.5 2.5 48 4334 0. 193 12.5 265 265
3×120 2.5 2.6 51 5181 0. 153 12.5 305 300
3×150 2.5 2.7 54 6154 0. 124 12.5 345 340
3×185 2.5 2.9 58 7334 0.0991 12.5 400 380
3×240 2.6 3 63 9146 0.0754 12.5 470 435
3×300 2.8 3.2 69 11176 0.0601 12.5 535 485
3×400 3 3.5 77 14359 0.047 12.5 620 520

                                                                 N2XSEY 3.6/6kV

Nom.Cross-
section of
conductor
Insulation
Thickness
Sheath
Thickness
Approx O.D. Approx
Weight
Max.D.C.Resistance of Conductor
(20℃)
Test Voltage   A.C Current Rating
mm² mm mm mm kg/km Ω/km kV/5min In air (A) In soil(A)
1×25 3.4 2 20 598 0.727 21 140 150
1×35 3.4 2 22 719 0.524 21 175 180
1×50 3.4 2 23 884 0.387 21 205 215
1×70 3.4 2 24 1097 0.268 21 260 265
1×95 3.4 2 26 1378 0. 193 21 315 315
1×120 3.4 2 28 1658 0. 153 21 365 360
1×150 3.4 2 30 1967 0. 124 21 415 405
1×185 3.4 2 31 2335 0.0991 21 475 455
1×240 3.4 2 34 2908 0.0754 21 565 530
1×300 3.4 2 36 3507 0.0601 21 645 595
1×400 3.4 2.5 39 4503 0.047 21 750 680
1×500 3.4 2.5 42 5479 0.0366 21 865 765
1×630 3.4 2.5 48 6952 0.0283 21 990 860
1×800 3.4 2.6 52 7120 0.0221 21 1140 950
1×1000 3.4 2.8 57 10500 0.0176 21 1250 1040
3×25 3.4 2.3 41 895 0.727 21 120 125
3×35 3.4 2.4 44 2293 0.524 21 145 155
3×50 3.4 2.5 46 2812 0.387 21 175 180
3×70 3.4 2.6 50 3508 0.268 21 220 220
3×95 3.4 2.7 53 4402 0. 193 21 265 265
3×120 3.4 2.8 56 5319 0. 153 21 305 300
3×150 3.4 2.9 59 6309 0. 124 21 350 340
3×185 3.4 3 62 7319 0.0991 21 395 380
3×240 3.4 3.2 68 9218 0.0754 21 470 435
3×300 3.4 3.4 72 11159 0.0601 21 535 485
3×400 3.4 3.6 81 15107 0.047 21 610 520

                                                                         N2XSEY 6/10kV

Nom.Cross-
section of
conductor
Insulation
Thickness
Sheath
Thickness
Approx O.D. Approx
Weight
Max.D.C.Resistance of Conductor
(20℃)
Test Voltage   A.C Current Rating
mm² mm mm mm kg/km Ω/km kV/5min In air (A) In soil(A)
1×25 4.5 1.8  23.0  680 0.7270  30.5 140 150
1×35 4.5 1.8  24.0  804 0.5240  30.5 175 180
1×50 4.5 1.9  25.0  984 0.3870  30.5 205 215
1×70 4.5 1.9  27.0  1201 0.2680  30.5 260 265
1×95 4.5 2.0  29.0  1490 0.1930  30.5 315 315
1×120 4.5 2.0  30.0  1765 0.1530  30.5 365 360
1×150 4.5 2.1  32.0  2091 0.1240  30.5 415 405
1×185 4.5 2.1  34.0  2452 0.0991  30.5 475 455
1×240 4.5 2.2  36.0  3034 0.0754  30.5 565 530
1×300 4.5 2.4  39.0  3672 0.0601  30.5 645 595
1×400 4.5 2.4  42.0  4646 0.0470  30.5 750 680
1×500 4.5 2.5  45.0  5651 0.0366  30.5 865 765
1×630 4.5 2.5  50.0  7154 0.0283  30.5 990 860
1×800 4.5 2.7  55.0  8750 0.0221  30.5 1140 950
1×1000 4.5 2.9  59.0  10727 0.0176  30.5 1250 1040
3×25 4.5 2.4  46.0  2573 0.7270  30.5 120 125
3×35 4.5 2.6  48.0  2985 0.5240  30.5 145 155
3×50 4.5 2.7  51.0  3529 0.3870  30.5 175 180
3×70 4.5 2.8  55.0  4197 0.2680  30.5 220 220
3×95 4.5 2.9  58.0  5230 0.1930  30.5 265 265
3×120 4.5 3.0  61.0  6120 0.1530  30.5 305 300
3×150 4.5 3.1  64.0  7207 0.1240  30.5 350 340
3×185 4.5 3.2  68.0  8378 0.0991  30.5 395 380
3×240 4.5 3.4  73.0  10177 0.0754  30.5 470 435
3×300 4.5 3.5  77.0  12159 0.0601  30.5 535 485
3×400 4.5 3.8  86.0  15641 0.0470  30.5 610 520

                                                                         N2XSEY 8.7/15kV

Nom.Cross-
section of
conductor
Insulation
Thickness
Sheath
Thickness
Approx O.D. Approx
Weight
Max.D.C.Resistan
ce of Conductor
(20℃)
Test Voltage   A.C Current Rating
mm² mm mm mm kg/km Ω/km kV/5min In air (A) In soil(A)
1×35 5.5 1.9 25 979 0.524 42 170 180
1×50 5.5 1.9 27 1155 0.387 42 205 215
1×70 5.5 2 28 1393 0.268 42 260 265
1×95 5.5 2 30 1681 0. 193 42 315 315
1×120 5.5 2 32 1979 0. 153 42 360 360
1×150 5.5 2. 1 33 2301 0. 124 42 410 405
1×185 5.5 2.2 35 2718 0.0991 42 470 455
1×240 5.5 2.2 37 3302 0.0754 42 555 530
1×300 5.5 2.3 39 3941 0.0601 42 640 595
1×400 5.5 2.4 43 4931 0.047 42 745 680
1×500 5.5 2.5 47 5956 0.0366 42 885 765
1×630 5.5 2.6 51 7769 0.0283 42 980 860
1×800 5.5 2.8 55 8945 0.0221 42 1100 950
1×1000 5.5 2.9 61 10918 0.0176 42 1230 1040
1×1200 5.5 3.1 65 12900 0.0151 42 1320 1100
3×35 5.5 2.7 53 3348 0.524 42 140 155
3×50 5.5 2.9 55 3904 0.387 42 165 180
3×70 5.5 2.9 59 4623 0.268 42 210 220
3×95 5.5 3 62 5593 0. 193 42 255 265
3×120 5.5 3. 1 66 6495 0. 153 42 290 300
3×150 5.5 3.2 69 7637 0. 124 42 330 340
3×185 5.5 3.4 72 8803 0.0991 42 435 380
3×240 5.5 3.5 77 10729 0.0754 42 495 435
3×300 5.5 3.7 82 12723 0.0601 42 565 485
3×400 5.5 3.9 90 16207 0.047 42 640 520

                                                                         N2XSEY 12/20kV

Nom.Cross-
section of
conductor
Insulation
Thickness
Sheath
Thickness
Approx O.D. Approx
Weight
Max.D.C.Resistance of Conductor
(20℃)
Test Voltage   A.C Current Rating
mm² mm mm mm kg/km Ω/km kV/5min In air (A) In soil(A)
1×50 8 2 33 1560 0.387 63 210 215
1×70 8 2.1 35 1840 0.268 63 260 265
1×95 8 2.1 36 2140 0. 193 63 320 315
1×120 8 2.2 38 2450 0. 153 63 370 360
1×150 8 2.2 39 2790 0. 124 63 420 405
1×185 8 2.3 41 3200 0.0991 63 480 455
1×240 8 2.3 43 3800 0.0754 63 565 530
1×300 8 2.4 45 4460 0.0601 63 650 595
1×400 8 2.5 49 5530 0.047 63 755 680
1×500 8 2.6 53 6160 0.0366 63 865 765
1×630 8 2.7 56 8020 0.0283 63 1000 860
3×50 8 2.8 55 5290 0.387 63 175 180
3×70 8 2.9 59 6240 0.268 63 220 220
3×95 8 3 62 7360 0. 193 63 255 265
3×120 8 3.1 66 8350 0. 153 63 290 300
3×150 8 3.2 69 9520 0. 124 63 330 340
3×185 8 3.4 72 10830 0.0991 63 435 380
3×240 8 3.5 77 12810 0.0754 63 495 435
3×300 8 3.7 82 14920 0.0601 63 565 485
3×400 8 3.9 90 18110 0.047 63 640 520

                                                                         N2XSEY 18/30kV

Nom.Cross-
section of
conductor
Insulation
Thickness
Sheath
Thickness
Approx O.D. Approx
Weight
Max.D.C.Resistance of Conductor
(20℃)
Test Voltage   A.C Current Rating
mm² mm mm mm kg/km Ω/km kV/5min In air (A) In soil(A)
1×50 9.3 2 37 1609 0.387 73.5 220 215
1×70 9.3 2.5 38 1850 0.268 73.5 270 265
1×95 9.3 2.5 40 2193 0.193 73.5 330 315
1×120 9.3 2.5 42 2498 0.153 73.5 375 360
1×150 9.3 2.5 44 2830 0.124 73.5 425 400
1×185 9.3 2.5 45 3248 0.0991 73.5 485 455
1×240 9.3 2.5 48 3881 0.0754 73.5 560 525
1×300 9.3 3 50 4529 0.0601 73.5 650 595
1×400 9.3 3 53 5570 0.047 73.5 760 680
1×500 9.3 3 55 6690 0.0366 73.5 875 775
1×630 9.3 3.1 60 8099 0.0283 73.5 1000 875
1×800 9.3 3.1 65 9752 0.0221 73.5 1130 970
1×1000 9.3 3.2 70 11781 0.0176 73.5 1250 1060
1×1200 9.3 3.3 74 13784 0.0151 73.5 1350 1120
3×50 9.3 3.5 76 4817 0.387 73.5 185 200
3×70 9.3 3.6 80 5668 0.268 73.5 230 250
3×95 9.3 3.7 83 6642 0. 193 73.5 280 300
3×120 9.3 3.8 86 7603 0. 153 73.5 310 330
3×150 9.3 3.9 89 8678 0. 124 73.5 360 380
3×185 9.3 4 93 9965 0.0991 73.5 400 425
3×240 9.3 4.2 98 11914 0.0754 73.5 470 490
3×300 9.3 4.3 102 14026 0.0601 73.5 540 555
3×400 9.3 4.6 110 17266 0.047 73.5 610 625

                                                                         N2XSEY 21/35kV

Nom.Cross-
section of
conductor
Insulation
Thickness
Sheath
Thickness
Approx O.D. Approx
Weight
Max.D.C.Resistance of Conductor
(20℃)
Test Voltage   A.C Current Rating
mm² mm mm mm kg/km Ω/km kV/5min In air (A) In soil(A)
1×50 10.5 2.2 39 1758 0.387 91 220 215
1×70 10.5 2.4 41 2038 0.268 91 270 265
1×95 10.5 2.4 42 2355 0. 193 91 330 315
1×120 10.5 2.4 44 2666 0. 153 91 375 360
1×150 10.5 2.5 45 3031 0. 124 91 425 400
1×185 10.5 2.5 47 3427 0.0991 91 485 455
1×240 10.5 2.6 49 4070 0.0754 91 560 525
1×300 10.5 2.7 51 4748 0.0601 91 650 595
1×400 10.5 2.8 55 5801 0.047 91 760 680
1×500 10.5 2.9 58 6623 0.0366 91 875 775
1×630 10.5 3 62 8211 0.0283 91 1000 875
1×800 10.5 3.1 68 10014 0.0221 91 1130 970
1×1000 10.5 3.3 72 12078 0.0176 91 1250 1060
1×1200 10.5 3.4 76 14100 0.0151 91 1350 1120
3×50 10.5 3.7 81 6728 0.387 91 185 200
3×70 10.5 3.8 84 7581 0.268 91 230 250
3×95 10.5 3.9 88 8630 0. 193 91 280 300
3×120 10.5 4 91 9688 0. 153 91 310 330
3×150 10.5 4.1 95 11017 0. 124 91 360 380
3×185 10.5 4.2 98 12390 0.0991 91 400 425
3×240 10.5 4.4 103 14427 0.0754 91 470 490
3×300 10.5 4.5 108 15940 0.0601 91 540 555
3×400 10.5 4.8 116 19346 0.047 91 610 625

                                                                         N2XSEY 26/35kV

Cable Structure

● Conductor:Compact stranded copper conductor,Cl.2 as per IEC 60228
● Conductor Screen:Semi-conductor
● Insulation:XLPE(cross-linked polyethylene)rated at 90℃
● Insulation Screen:Semi-conductor
● Screen:Copper tape

● Filler:non hygroscopic filler(pp)
● Sheath:PVC or FR-PVC type ST2/ST8 to IEC 60502,black

Code Designation

YJ: XLPE insulation

V: PVC sheath

ZR: Flame resistant

European Union:N2XSEY/NA2XSEY

Application

For indoors and outdoors wiring work.Able to stand certain level traction during installation,but not external mechanical forces.single core cable wiring job in magnetic ducts is forbidden.

Standard

International:IEC 60502,IEC 60228,(IEC 60332-3 for ZR-YJV only)

China:GB/T  12706,(GB/T 18380-3 for ZR-YJV only)

European standard:DIN VDE0276-620,HD620S2,IEC/EN 60228,IEC/EN 60502-2,

                            Flame Retardant according to IEC/EN 60332-1-2

Indonesian Standard:Conductor:SNI IEC 60228/Insulation:SNI IEC 60502-2

Other standards such as BS,DIN and ICEA upon request

Technical Data

Rated voltage:3.6/6 KV,6/10kV,8.7/15kV,12/20kV,18/30kV,21/35kV,26/35kV

Maximum Conductor Temperature:under normal (90℃),emergency (130℃)or short circuit no more than 5s(250℃)conditions.

Min.Ambient Temp.-20℃,Installation  Temp.0℃

Min.Bending Radius:20×cable O.D for single core 

                             15×cable O.D for multi core