ASTM B399
Code Name Conductor Size Stranding Sectional Area Diameter of Conductor Linear Mass Rated Strength Max. D.C. Resistance
at 20°C
AWG(MCM) No./mm mm² mm kg/km daN Ω/km
Alton 4 7/1.96 21.14  5.89  57.89  685 1.5860 
48.69(4) 7/2.12 24.67  6.35  67.56  799 1.3557 
Ames 2 7/2.47 33.65  7.42  92.14  1091 0.9987 
77.47(2) 7/2.67 39.26  8.02  107.50  1275 0.8547 
Azusa 1/0 7/3.12 53.49  9.35  146.50  1733 0.6259 
123.3(1/0) 7/3.37 62.46  10.11  171.00  2019 0.5365 
Anaheim 2/0 7/3.50 67.45  10.52  184.70  2090 0.4974 
155.4(2/0) 7/3.78 78.75  11.35  215.16  2447 0.4264 
Amherst 3/0 7/3.93 85.00  11.79  232.70  2641 0.3945 
195.7(3/0) 7/4.25 99.20  12.75  271.50  3079 0.3373 
Alliance 4/0 7/4.42 107.20  13.26  293.70  3334 0.3119 
246.9(4/0) 7/4.77 125.10  14.30  342.60  3885 0.2678 
250 19/2.91 126.70  14.58  346.90  3977 0.2651 
Butte 300 19/3.19 152.10  15.89  418.60  4772 0.2206 
312.8 19/3.26 158.50  16.31  434.00  4976 0.2112 
Canton 350.5 19/3.45 177.30  17.25  485.50  5333 0.1886 
394.5 19/3.66 199.00  18.31  547.40  6016 0.1676 
Cairo 400 19/3.69 202.70  18.44  555.10  6098 0.1649 
450 19/3.91 228.00  19.56  624.40  6862 0.1468 
465.4 19/3.98 235.80  19.89  645.70  7097 0.1431 
Darien 500 19/4.12 253.40  20.60  693.60  7617 0.1322 
550 37/3.10 278.70  21.67  762.90  8555 0.1200 
559.5 19/4.36 283.50  21.79  776.30  8525 0.1181 
Elgin 600 37/3.23 304.00  22.63  832.00  9330 0.1105 
650 37/3.37 329.40  23.57  909.80  10105 0.1015 
Flint 652.4 19/4.71 330.60  23.55  970.60  9942 0.1012 
700 37/3.49 354.50  24.46  910.60  10401 0.09464 
740.8 37/3.59 375.40  25.15  1028 11013 0.08944 
750 37/3.62 380.20  25.32  1041 11216 0.08796 
Greeley 800 37/3.73 405.40  26.14  1109 11930 0.08285 
900 37/3.96 456.30  27.74  1249 13460 0.07351 
927.2 37/4.02 469.80  28.14  1287 13868 0.07133 
1000 37/4.18 506.70  29.24  1388 14887 0.06597 
1077.4 61/3.38 483.40  30.42  1496 15907 0.06120 
1165.1 61/3.51 523.70  31.59  1617 17233 0.05675 
1250 61/3.63 633.30  32.67  1733 18354 0.05306 
1259.6 61/3.65 564.00  32.85  1748 18558 0.05248 
1348.8 61/3.78 604.20  34.02  1872 19884 0.04893 
1438.2 61/3.90 644.50  35.10  1997 21209 0.04597 
1500 61/3.98 760.00  35.82  2081 22127 0.04414 
1750 61/4.30 886.70  38.70  2429 25798 0.03781 

 

EN 51082
Code Name Area No. of wires Diameter Mass per unit length Rated Strength DC Resistance
Wire Cond.
mm²   mm mm kg/km kN Ω/km
Box 18.8  7 1.85 5.55  51.4 5.55 1.7480 
Acacia 23.8  7 2.08 6.24  64.9 7.02 1.3828 
Almond 30.1  7 2.34 7.02  82.2 8.88 1.0926 
Cedar 35.5  7 2.54 7.62  96.8 10.46 0.9273 
Deodar 42.2  7 2.77 8.31  115.2 12.44 0.7797 
Fir 47.8  7 2.95 8.85  130.6 14.11 0.6875 
Hazel 59.9  7 3.3 9.90  163.4 17.66 0.5494 
Pine 71.6  7 3.61 10.8  195.6 21.14 0.4591 
Holly 84.1  7 3.91 11.7  229.5 24.79 0.3913 
Willow 89.7  7 4.04 12.1  245.0  26.47 0.3665 
Oak 118.9  7 4.65 14.0  324.5 35.07 0.2767 
Mulberry 150.9  19 3.18 15.9  414.3 44.52 0.2192 
Ash 180.7  19 3.48 17.4  496.1 53.31 0.1830 
Elm 211.0  19 3.76 18.8  579.2 62.24 0.1568 
Poplar 239.4  37 2.87 20.1  659.4 70.61 0.1387 
Sycamore 303.2  37 3.23 22.6  835.2 89.40  0.1095 
Upas 362.1  37 3.53 24.7  997.5 106.82 0.0917 
Yew 479.0  37 4.06 28.4  1319.6 141.31 0.0693 
Totara 498.1  37 4.14 29.0  1372.1 146.93 0.0666 
Rubus 586.9  61 3.5 31.5  1622 173.13 0.5670 
Sorbus 659.4  61 3.71 33.4  1822.5 194.53 0.0505 
Araucaria 821.1  61 4.14 37.3  2269.4 242.24 0.0406 
Redwood 996.2  61 4.56 41.0  2753.2 293.88 0.0334 

 

IEC 61089
Code Number Area No. of wires Diameter Linear Mass Rated Strength Max. D.C. Resistance at 20℃
Wire Cond.
mm²   mm mm kg/km kN Ω/km
16 18.4 7 1.83 5.49 50.4 5.43 1.7896
25 28.8 7 2.29 6.87 78.7 8.49 1.1453
40 46.0  7 2.89 8.67 125.9 13.58 0.7158
63 72.5 7 3.63 10.80  198.3 21.39 0.4545
100 115 19 2.78 13.90  316.3 33.95 0.2877
125 144 19 3.10  15.50  395.4 42.44 0.2302
160 184 19 3.51 17.55 506.1 54.32 0.1798
200 230 19 3.93 19.65 632.7 67.91 0.1439
250 288 19 4.39 21.95 790.8 84.68 0.1151
315 363 37 3.53 24.71 998.9 106.95 0.0916
400 460 37 3.98 27.86 1268.4 135.81 0.0721
450 518 37 4.22 29.54 1426.9 152.79 0.0641
500 575 37 4.45 31.15 1585.5 169.76 0.0577
560 645 61 3.67 33.03 1778.4 190.14 0.0516
630 725 61 3.89 35.01 2000.7 213.9 0.0458
710 817 61 4.13 37.17 2254.8 241.07 0.0407
800 921 61 4.38 39.42 2540.6 271.62 0.0361
900 1036 91 3.81 41.91 2861.1 305.58 0.0632
1000 1151 91 4.01 44.11 3179 339.53 0.0289
1120 1289 91 4.25 46.75 3560.5 380.27 0.0258
1250 1439 91 4.49 49.39 3973.7 424.41 0.0231

Cable Structure

Conductor:All aluminium alloy

Standard

ASTMB399    EN 51082  IEC 61089

Application

AAAC is made by twisting alloy wires of high-purity aluminum and silicon.

Due to its advantages of good conductivity and strong corrosion resistance,

it is widely used in power transmission,distribution and municipal engineering.

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.