Parameter
Nom.Cross- section Area |
overall diameter |
cable Weight |
mm² | mm | km/kg |
2 × 1.5 | 10.4 | 155 |
3 × 1.5 | 10.9 | 178 |
4 × 1.5 | 11.8 | 210 |
5 × 1.5 | 12.7 | 248 |
7 × 1.5 | 13.7 | 300 |
8 × 1.5 | 14.7 | 340 |
10 × 1.5 | 17.0 | 427 |
12 × 1.5 | 17.5 | 453 |
14 × 1.5 | 18.4 | 525 |
18 × 1.5 | 20.3 | 652 |
21 × 1.5 | 21.4 | 689 |
25 × 1.5 | 24.3 | 835 |
32 × 1.5 | 26.2 | 1017 |
34 × 1.5 | 26.9 | 1094 |
37 × 1.5 | 27.2 | 1126 |
42 × 1.5 | 29.4 | 1312 |
50 × 1.5 | 32.2 | 1534 |
2 × 2.5 | 11.2 | 190 |
3 × 2.5 | 11.8 | 223 |
4 × 2.5 | 12.7 | 263 |
5 × 2.5 | 13.8 | 317 |
7 × 2.5 | 14.9 | 388 |
8 × 2.5 | 16 | 440 |
10 × 2.5 | 18.6 | 557 |
12 × 2.5 | 19.2 | 599 |
14 × 2.5 | 20.1 | 692 |
18 × 2.5 | 22.3 | 868 |
19 × 2.5 | 22.8 | 890 |
21 × 2.5 | 23.6 | 930 |
25 × 2.5 | 26.8 | 1123 |
34 × 2.5 | 30.2 | 1295 |
42 × 2.5 | 32.0 | 1725 |
2 × 4 | 13.2 | 271 |
3 × 4 | 13.9 | 321 |
4 × 4 | 15.1 | 385 |
5 × 4 | 16.5 | 468 |
7 × 4 | 17.9 | 580 |
3 × 6 | 15.2 | 407 |
4 × 6 | 16.6 | 495 |
5 × 6 | 20.3 | 707 |
7 × 6 | 21.9 | 826 |
3 × 10 | 19.6 | 682 |
4 × 10 | 21.2 | 829 |
5 × 10 | 23.0 | 990 |
7 × 10 | 24.9 | 1236 |
3 × 16 | 219 | 924 |
4 × 16 | 23.9 | 1143 |
5 × 16 | 26.1 | 1381 |
7 × 16 | 28.5 | 1757 |
3 × 25 | 25.7 | 1332 |
4 × 25 | 28.1 | 1657 |
5 × 25 | 31.0 | 2030 |
3 × 35 | 28.9 | 1754 |
4 × 35 | 32.3 | 2244 |
5 × 35 | 35.6 | 2746 |
3 × 50 | 33.7 | 2437 |
4 × 50 | 37.1 | 3067 |
5 × 50 | 411 | 3777 |
3 × 70 | 378 | 3207 |
4 × 70 | 41.6 | 4045 |
5 × 70 | 46.4 | 5021 |
3 × 95 | 43.3 | 4277 |
4 × 95 | 48.0 | 5442 |
5 × 95 | 53.2 | 6710 |
3 × 120 | 47.2 | 5234 |
4 × 120 | 52.2 | 6653 |
5 × 120 | 58.1 | 8242 |
3 × 150 | 52.1 | 6453 |
4 × 150 | 58.0 | 8262 |
3 × 185 | 57.6 | 7923 |
4 × 185 | 63.7 | 10078 |
3 × 240 | 64.2 | 10054 |
4 × 240 | 71.7 | 12925 |
Cable Structure
● Conductor:Class 5 flexible stranded bare copper
● Insulation:XLPE
● Sheath: Low Smoke Halogen Free outer sheath,Grey Colour or black colour
Code Designation
2XSLH
Application
low smoke halogen-free flexible connecting cable for instrumentation and control equipment for tooling machinery,production lines,and in flexible applications with free movement and no tensile load.Suitable for use in dry,ambient and wet rooms.These cables are not suitable for outdoor or underground installations.
Standard
International:Conductor refer to IEC-60228,class 5,Flame retardancy refer to IEC-60332-1/IEC-60332-24(Cat C),LSZH standard refer to IEC-60754-1/IEC-60754-2/IEC-61034-2
Other standards such as IEC,BS,DIN and ICEA upon request
Technical Data
Voltage Rating Uo/U:0.6/1kV
Max.working temperature:Fixed:+90℃
Min.laying temperature:-5℃
Minimum Bending Radius :15×overall diameter
Certificates
CE,RoHS,CCC,KEMA and more others at request