Parameter
No.cores × cross sec. |
AVG. Insulation Thickness |
AVG.Jacket (Sheath) Thickness |
Approx. O.D. | Approx. Weight | Conductor Resistance at 20°C |
mm² | mm | mm | mm | kg/km | Ω/km |
1×2.5 | 0.8 | 0.8 | 5 | 47 | 8.21 |
1×4 | 0.8 | 0.9 | 5.6 | 64 | 5.09 |
1×6 | 0.8 | 0.9 | 6.2 | 87 | 3.39 |
1×10 | 1 | 1 | 7.5 | 132 | 1.95 |
1×16 | 1 | 1 | 8.7 | 197 | 1.24 |
1×25 | 1.2 | 1.2 | 10.8 | 304 | 0.795 |
1×35 | 1.2 | 1.2 | 12.4 | 413 | 0.565 |
1×50 | 14.4 | 576 | 0.393 | ||
1×70 | 16.2 | 781 | 0.277 | ||
1×95 | 18.3 | 1036 | 0.210 | ||
1×120 | 19.9 | 1287 | 0.164 | ||
1×150 | 22.1 | 1607 | 0.132 | ||
1×185 | 24.8 | 1993 | 0.108 | ||
1×240 | 27.8 | 2555 | 0.0817 |
Cable Structure
Bare copper,tinned,finely stranded according
to IEC 60228 cl.5
Double-insulated
Insulation cross-linked Polyolefin
Outer sheath cross-linked Polyolefin
Sheath colour black,red or blue
Properties
Ozone resistant acc.to EN 50396
•Weather and UV resistant acc.to HD 605/A1
•Halogen-free acc.to EN 50267-2-1,EN 60684-2
•Resistant to acid and bases acc.toEN 60811-2-1 Flame-resistant acc.to VDE 0482-332-1-2,DIN EN 60332-1-2,IEC 60332-1
•Very robust and abraison-resistant sheath acc.to DiN EN 53516
•Resistant to short-circuits up to 200'C thanks to their double insulation;short-circuits temperature 200'C/5 sec.
•Hydrolysis and ammoniac resistant
Application
Single core PV cable meet the Varying needs of the Solar Industry.Applications include connection to module junction boxes; required cable routing in balance system integration Rated 1000V
Technical Data
•Temperature range -40℃ to +90 ℃ Max.temp.at conductor+120C
•Nominal voltage According to VDE U,/U 600/1000 V AC 1800 V DC conductor/conductor
•AC test voltage 10000 V
foued installation approx. 8 x outer diameters flexóing 10 × cable diameter
Standard
TÜV(2 PfG 1169/08.2007,R60025298) RoHS complant