Siga

Nom.Cross-section Area overall diameter cable Weight DC Resistance at 20℃ Conductor min
mm² mm km/kg Ω/km
3×1 11.2 196 19.5
3 × 1.5 10.9 187 13.3
3 × 2.5 13.5 326 7.98
3×4 15.1 391 4.95
4 × 0.75 11.4 214 26
4×1 11.8 231 19.5
4 × 1.5 12.2 265 13.3
4 × 2.5 14.6 379 7.98
4×4 16.7 557 4.95
4×6 18.7 723 3.3
4×10 21.9 1267 1.91
4×16 26.4 1763 1.21
4×25 32.5 2750 0.78
4×35 35.7 3497 0.554
4×50 41.1 4937 0.386
4×70 48 7480 0.272
4×95 51.2 10220 0.206
5 × 0.75 12.1 250 26
5×1 12.6 270 19.5
5 × 1.5 13.3 289 13.3
Nom.Cross-section Area overall diameter cable Weight DC Resistance at 20℃ Conductor min
mm² mm km/kg Ω/km
5×4 18.6 695 4.95
5×6 20.7 984 3.3
5×10 24.1 1635 1.91
5×16 28.8 2720 1.21
5×25 35.7 3490 0.78
7 × 0.75 13 319 26
7×1 14.5 289 19.5
7 × 1.5 16 416 13.3
7 ×2.5 17.9 590 7.98
12 × 0.75 15.8 437 26
12×1 17.4 493 19.5
12×1.5 19.6 641 13.3
12 × 2.5 21.9 897 7.98
18×0.75 18 588 26
18×1 20.7 658 19.5
18×1.5 23.4 872 13.3
18×2.5 26.1 1355 7.98
25×0.75 22.8 746 26
25×1 24.8 870 19.5
25×1.5 28.2 1211 13.3
25×2.5 31.9 1995 7.98

                                       

Tsarin Kebul

● Conductor:Class 5 flexible stranded bare copper

● Insulation:PVC

● Bedding PVC

● Screen:TinnedCopperBraided 70%Coverage

● Sheah:Special PVC-Compound

Tsarin Code

YSLYCY

Aikace-aikace

Flexible power,process control and instrumentation cable for industry,machinery and outdoor environment.The YSLYCY cable is resistant against most usual chemicals,oil and grease.This cable is suitable for indoor and outdoor application.

Daidaitawa

Europeanstandard :VDE 0482-332-1-2,EN 60881-404

Fire Retardantaccording to IEC/EN 60332-1-2

Other standardssuch as IEC,BS,DIN and ICEAuponrequest

Bayanan Fasaha

Voltage Rating Uo/U:0.6/1kV

Temperature Rating:Fixed:-20℃ to +70℃

            Installation:-5℃ to+70℃

Minimum Bending Radius Fixed:5×overalldiameter

                                   Flexed:10×overall diameter

Takaddun shaida

CE, RoHS, CCC, KEMA da sauran su akan buƙata