Parameter
PVC FLAT 2 CORES | ||||||
Cross section (mm2) | Type of conductor | Nom.insulation thick.(mm) | Nom.outer sheath thick.(mm) | Earth cond.sect(mm2) | Nom.over.diam. | Approx.weight(kg/100m) |
1 | Solid copper | 0.6 | 0.9 | / | 6.5×4.2 | 5.00 |
1.5 | Stranded copper | 0.6 | 0.9 | / | 7.2×4.5 | 6.20 |
2.5 | Stranded copper | 0.7 | 1.0 | / | 8.9×5.4 | 9.70 |
4 | Stranded copper | 0.8 | 1.1 | / | 10.5×6.3 | 14.00 |
6 | Stranded copper | 0.8 | 1.1 | / | 11.6×6.9 | 19.00 |
10 | Stranded copper | 1.0 | 1.2 | / | 14.2×8.3 | 29.00 |
16 | Stranded copper | 1.0 | 1.3 | / | 16.3×9.5 | 42.00 |
PVC FLAT 3 CORES | ||||||
Cross section (mm2) | Type of conductor | Nom.insulation thick.(mm) | Nom.outer sheath thick.(mm) | Earth cond.sect(mm2) | Nom.over.diam. | Approx.weight(kg/100m) |
1.5 | Stranded copper | 0.6 | 0.9 | / | 9.9×4.5 | 8.80 |
PVC FLAT 3 CORES +EARTH | ||||||
Cross section (mm2) | Type of conductor | Nom.insulation thick.(mm) | Nom.outer sheath thick.(mm) | Earth cond.sect(mm2) | Nom.over.diam. | Approx.weight(kg/100m) |
1 | Solid copper | 0.6 | 0.9 | 1 | 8.9×4.2 | 7.74 |
1.5 | Stranded copper | 0.6 | 0.9 | 1.5 | 9.9×4.5 | 8.86 |
2.5 | Stranded copper | 0.7 | 1.0 | 2.5 | 12.2×5.4 | 14.03 |
4 | Stranded copper | 0.8 | 1.1 | 2.5 | 13.9×6.3 | 18.65 |
6 | Stranded copper | 0.8 | 1.1 | 2.5 | 15.0×6.9 | 23.04 |
10 | Stranded copper | 1.0 | 1.2 | 4 | 18.3×8.3 | 36.05 |
16 | Stranded copper | 1.0 | 1.3 | 6 | 21.0×9.5 | 51.46 |
PVC FLAT 3 CORES +EARTH |
||||||
Cross section (mm2) | Type of conductor | Nom.insulation thick.(mm) | Nom.outer sheath thick.(mm) | Earth cond.sect(mm2) | Nom.over.diam. | Approx.weight(kg/100m) |
1.5 | Stranded copper | 0.6 | 0.9 | 1.5 | 12.6×4.5 | 11.54 |
2.5 | Stranded copper | 0.7 | 1 | 2.5 | 15.7×5.4 | 18.31 |
Kabelstructuur
Conductor material :copper
Conductor shape: Circular
Insulation: V-90
Outer Sheath: PVC
Codeaanduiding
TPS Cable
Sollicitatie
Flat TPS is more common than circular, and is used for fixed wiring of domestic and industrial lighting, power outlets, appliances, and HVAC units. Circular TPS is common in industrial and commercial installations but generally not in domestic installations.
Standaard
IAS/NZS 1125; AS/NZS 5000.2
2&3 core flat,
450/750V V-90 insulated,
PVC sheathed to AS/NZS 5000.2,
Copper conductors,90℃.
Andere normen zoals BS,DIN en ICEA op aanvraag
Technische data
Nominale spanning: 450/750V
Bending factor when installed:4(×D)
Bending factor when laying:6(×D)
Certificaten
CE, RoHS, CCC, KEMA en meer anderen op aanvraag
Details over de verpakking
Kabel wordt geleverd met houten haspels, houten trommels, stalen houten trommels en spoelen, of volgens uw vereisten.
Kabeluiteinden zijn afgedicht met BOPP zelfklevende tape en niet-hygroscopische afsluitdoppen om de kabeluiteinden tegen vocht te beschermen. De vereiste markering moet worden afgedrukt met weerbestendig materiaal op de buitenkant van de trommel, afhankelijk van de eisen van de klant.
Aflevertijd
Normaal gesproken binnen 7-14 dagen (afhankelijk van de bestelhoeveelheid). Wij zijn in staat om te voldoen aan de meest strikte leveringsschema's per inkooporder. Het halen van de deadline heeft altijd de hoogste prioriteit, aangezien elke vertraging in de levering van kabel kan bijdragen aan de algehele projectvertraging en kostenoverschrijdingen.
Verzendhaven
Tianjin, Qingdao of andere havens volgens uw vereisten.
Zeevracht
De FOB/C&F/CIF-offerte is allemaal beschikbaar.
Diensten beschikbaar
Proefmonsters zijn conform uw productie- of lay-outontwerp.
Vragen binnen 12 uur beantwoord, e-mail binnen een uur beantwoord.
Goed opgeleide en ervaren verkopers staan klaar.
Het onderzoeks- en ontwikkelingsteam is beschikbaar.
Aangepaste projecten zijn zeer welkom.
Op basis van uw bestelgegevens kan de productie worden afgestemd op de productielijn.
Inspectierapport vóór verzending kan worden ingediend door onze QC-afdeling, of volgens de door u aangewezen derde partij.
Goede service na verkoop.