2XSLH 0.6/1kV Cu Conductors with XLPE Insulated and with Low Smoke Zero Halogen Sheathed Control Cable
Parameter
Name.Cross- section Area |
overall diametri |
cable Pondus |
mm² | mm | km/kg |
2 1.5 | 10.4 | 155 |
3 1.5 | 10.9 | 178 |
4 1.5 | 11.8 | 210 |
5 1.5 | 12.7 | 248 |
7 1.5 | 13.7 | 300 |
8 × 1.5 | 14.7 | 340 |
10 × 1.5 | 17.0 | 427 |
12 × 1.5 | 17.5 | 453 |
14 × 1.5 | 18.4 | 525 |
18 × 1.5 | 20.3 | 652 |
21 × 1.5 | 21.4 | 689 |
25 × 1.5 | 24.3 | 835 |
32 × 1.5 | 26.2 | 1017 |
34 × 1.5 | 26.9 | 1094 |
37 × 1.5 | 27.2 | 1126 |
42 × 1.5 | 29.4 | 1312 |
50 × 1.5 | 32.2 | 1534 |
2 2.5 | 11.2 | 190 |
3 2.5 | 11.8 | 223 |
4 2.5 | 12.7 | 263 |
5 2.5 | 13.8 | 317 |
7 2.5 | 14.9 | 388 |
8 × 2.5 | 16 | 440 |
10 × 2.5 | 18.6 | 557 |
12 × 2.5 | 19.2 | 599 |
14 × 2.5 | 20.1 | 692 |
18 × 2.5 | 22.3 | 868 |
19 × 2.5 | 22.8 | 890 |
21 × 2.5 | 23.6 | 930 |
25 × 2.5 | 26.8 | 1123 |
34 × 2.5 | 30.2 | 1295 |
42 × 2.5 | 32.0 | 1725 |
2 4 | 13.2 | 271 |
3 4 | 13.9 | 321 |
4 4 | 15.1 | 385 |
5 4 | 16.5 | 468 |
7 4 | 17.9 | 580 |
3 6 | 15.2 | 407 |
4 6 | 16.6 | 495 |
5 6 | 20.3 | 707 |
7 6 | 21.9 | 826 |
3 × 10 | 19.6 | 682 |
4 × 10 | 21.2 | 829 |
5 × 10 | 23.0 | 990 |
7 × 10 | 24.9 | 1236 |
3 × 16 | 219 | 924 |
4 × 16 | 23.9 | 1143 |
5 × 16 | 26.1 | 1381 |
7 × 16 | 28.5 | 1757 |
3 × 25 | 25.7 | 1332 |
4 × 25 | 28.1 | 1657 |
5 × 25 | 31.0 | 2030 |
3 × 35 | 28.9 | 1754 |
4 × 35 | 32.3 | 2244 |
5 × 35 | 35.6 | 2746 |
3 × 50 | 33.7 | 2437 |
4 × 50 | 37.1 | 3067 |
5 × 50 | 411 | 3777 |
3 × 70 | 378 | 3207 |
4 × 70 | 41.6 | 4045 |
5 × 70 | 46.4 | 5021 |
3 × 95 | 43.3 | 4277 |
4 × 95 | 48.0 | 5442 |
5 × 95 | 53.2 | 6710 |
3 120 | 47.2 | 5234 |
4 × 120 | 52.2 | 6653 |
5 × 120 | 58.1 | 8242 |
3 150 | 52.1 | 6453 |
4 × 150 | 58.0 | 8262 |
3 185 | 57.6 | 7923 |
4 × 185 | 63.7 | 10078 |
3 × 240 | 64.2 | 10054 |
4 × 240 | 71.7 | 12925 |
Cable Structure
● Conductor:Class 5 flexible stranded bare copper
● Insulation:XLPE
● Sheath: Low Smoke Halogen Free outer sheath,Grey Colour or black colour
Code Designatio
2XSLH
Applicationem
low smoke halogen-free flexible connecting cable for instrumentation and control equipment for tooling machinery,production lines,and in flexible applications with free movement and no tensile load.Suitable for use in dry,ambient and wet rooms.These cables are not suitable for outdoor or underground installations.
Standard
International:Conductor refer to IEC-60228,class 5,Flame retardancy refer to IEC-60332-1/IEC-60332-24(Cat C),LSZH standard refer to IEC-60754-1/IEC-60754-2/IEC-61034-2
Alia signa postulantibus IEC, BS, DIN et ICEA
Technical data
Voltage Rating Uo/U:0.6/1kV
Max.working temperature:Fixed:+90℃
Min.laying temperature:-5℃
Minimum Bending Radius :15×overall diameter
Testimonia
CE, RoHS, CCC, KEMA, et plures alii ad petitionem