• Home
  • News
  • Premium N2XSEYBY/NA2XSEYBY MV XLPE Armored Cable | 3.6-20kV
júl . 31, 2025 03:00 Back to list

Premium N2XSEYBY/NA2XSEYBY MV XLPE Armored Cable | 3.6-20kV


The rapid evolution of high-voltage energy transmission and industrial automation has driven demand for robust and efficient cable solutions. Among these, the N2XSEYBY/NA2XSEYBY 3.6/6kV 6/10kV 8.7/15kV 12/20kV MEDIUM VOLTAGE Cu CONDUCTOR XLPE INSULATED MULTI-CORE STEEL TAPE ARMOURED CABLE emerges as a technological benchmark, lauded for its performance, safety, and longevity across petrochemical, metallurgy, municipal engineering, and energy domains.

Industry Trends: Demand for Reliable Medium Voltage Solutions

According to IMARC Group's 2023 research, the global medium voltage cable market will surpass USD 72.6 billion by 2028, forecasted at a CAGR of 6.1% (2023-2028). The increasing adoption of renewable energy, grid modernization, and the need for safe energy distribution propel the demand for advanced cables like the N2XSEYBY/NA2XSEYBY.

Technical Parameters: Product Specification Table

Parameter Specification Industry Standard
Product Name N2XSEYBY/NA2XSEYBY 3.6/6kV 6/10kV 8.7/15kV 12/20kV MEDIUM VOLTAGE Cu CONDUCTOR XLPE INSULATED MULTI-CORE STEEL TAPE ARMOURED CABLE IEC 60502, VDE 0276, GB/T 12706.2
Application Voltage 3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV IEC 60502-2
Conductor Material Copper (Cu), class 2 stranded IEC 60228
Insulation Material Cross-linked Polyethylene (XLPE) IEC 60502-2
Armouring Steel Tape Armored IEC 60502-2, DIN VDE
Core Arrangement 2-5 Multi-core
Operating Temp. 90°C (Conductor), 250°C (Short-circuit, 5s) IEC 60840
Outer Sheath Flame Retardant PVC/LSZH IEC 60332, IEC 60754
Minimum Bending Radius 15 x Outer Diameter IEC 60502
Testing Voltage 5kV / 10kV / 18kV / 24kV (5min) IEC 60228/IEC 60502
Certifications ISO 9001, CE, RoHS ISO, EU Directives

Manufacturing Process Illustration

1. Cu Conductor Stranding 2. XLPE Insulation Extrusion 3. Core Laying 4. Inner Sheath 5. Steel Tape Armouring 6. Outer Sheath Extrusion 7. Routine Testing 8. Delivery & Packing
  • Material: High-purity copper conductor guarantees superior conductivity and mechanical flexibility.
  • Manufacturing: XLPE insulation is extruded via advanced cross-linking process (dry cure/CCV lines) ensuring insulation integrity even at elevated temperatures.
  • Armouring: Galvanized steel tape provides mechanical protection against crush and impact forces, and enhances rodent and termite resistance.
  • Sheathing: Flame-retardant, halogen-free outer sheath options meet strict environmental and fire safety standards (IEC 60332, 60754).
  • Testing: 100% routine high-voltage, insulation resistance, and partial discharge tests (in accordance with IEC and ISO).
  • Service Life: Designed for 30+ years under nominal operating conditions (Ref: Industry forum discussions).

Advantages & Technology Highlights

  • XLPE Insulation: Cross-linked polyethylene boasts a dielectric strength of 20–30 kV/mm, significantly outperforming traditional PVC. This results in higher allowed operating temperatures (90°C normal, 250°C short-circuit) and extended aging resistance.
  • Cu Conductors: IEC 60228 Class 2 stranded copper ensures optimal flexibility, reducing installation fatigue, and maintains low electrical losses (1.72 μΩ⋅cm resistance).
  • Steel Tape Armouring: Double steel tape delivers +400% enhanced mechanical protection compared to unarmoured cables, per VDE 0276 testing data.
  • Environmental Resistance: Outer sheath options include LSZH (low smoke zero halogen) complying with IEC 60754, critical for tunnel, metro, and public infrastructure.
  • Custom Multi-core Configurations: Tailored solutions for complex distribution, from 2 to 5 core arrangements, supporting system reliability in industrial networks.
  • Stringent Testing: Each drum passes partial discharge (<2pc at rated voltage), insulation resistance, and spark tests per IEC 60502-2 and ISO 9001 QA protocols.

Factory/Brand Comparison Table

Factory
(Region)
Key Material Certifications Typical MOQ Custom Service Warranty
THCable
(China)
Cu+XLPE+Steel Tape ISO9001, IEC, RoHS, CE 500m Full spec & color
Laser-printed sheath
36 months
Prisma Kabel
(Germany)
Cu+XLPE+Steel Tape VDE, RoHS, ISO 1000m Custom sheath color 24 months
Nexans
(France)
Cu+XLPE+Steel Tape IEC, ISO 14001 Min. 1km Standard 24 months
LS Cable
(South Korea)
Cu+XLPE+Steel Tape IECB, KOSHA, RoHS 1500m Limited 24 months

Core Performance Data Comparison

Material Cost Breakdown - Pie Chart Reference

Cu Conductor (55%)   Steel Tape Armouring (14%)   XLPE Insulation (18%)   Outer Sheath (13%)

Custom Solutions & Service Workflow

Harnessing decades of engineering expertise, THCable offers bespoke design and production for N2XSEYBY/NA2XSEYBY 3.6/6kV 6/10kV 8.7/15kV 12/20kV MEDIUM VOLTAGE Cu CONDUCTOR XLPE INSULATED MULTI-CORE STEEL TAPE ARMOURED CABLE, supporting color coding, core numbering, armored type (single or double), and branded outsheath.

  • Technical consulting based on project site voltage, routing, and mechanical requirements
  • 3-day quick drawing and specification confirmation
  • Production with raw material traceability and batch inspection
  • Custom lengths, packaging, export marking
  • Support for international shipping, import documents, and on-site installation guidance
Request Custom Quotation

Application Scenarios & Typical Project Cases

1. Petrochemical Pipeline Network (Asia)
  • Adopted 8.7/15kV specification of N2XSEYBY/NA2XSEYBY in parallel feed installation, offering resistance to oil, chemicals, and rodent bites.
  • Result: Reduced annual accidental outage by 42% (compared to legacy EPR/PVC cables), with certified fire safety compliance (IEC 60332-3).
2. Metro Tunnel Systems (Europe)
  • Multi-core armored cables supplied for traction and lighting under stringent LSZH demand.
  • Result: Zero halogen emission during IEC 60754-1 tests, meeting EU Metro fire code; mechanical protection against vibration proved effective over a 7-year operation period.
3. Metallurgical Plant Expansion (Africa)
  • 12/20kV specification selected for rolling mill drive motors, providing robust anti-corrosion sheathing and enhanced mechanical armor strength.
  • Result: Service downtime due to cable failure dropped by 67%, confirmed by factory maintenance logs.
4. Water Treatment & Utility Tunnels
  • Deployed in underground pump wiring, the steel tape armoring ensures long-term subsoil burial reliability and mitigates moisture ingress.
  • Result: 24/7 continuous operation, with insulation resistance retention over 38,000 MΩ·km after 5 years on-site (3rd party test: SGS).

Professional FAQ on N2XSEYBY/NA2XSEYBY 3.6/6kV 6/10kV 8.7/15kV 12/20kV MEDIUM VOLTAGE Cu CONDUCTOR XLPE INSULATED MULTI-CORE STEEL TAPE ARMOURED CABLE

Q1: What is the primary conductor material used, and why?
A: High-purity copper (Cu), Class 2 stranded per IEC 60228, is utilized, providing superior conductivity, flexibility, and lower maintenance compared to aluminum.
Q2: How does XLPE insulation enhance cable performance versus PVC?
A: XLPE exhibits higher dielectric strength, operates reliably at up to 90°C, and offers superior aging, chemical, and moisture resistance, which extends lifespan and electrical integrity.
Q3: What is the IEC 60502-2 testing protocol for armoured medium voltage cables?
A: IEC 60502-2 mandates routine checks including AC voltage withstand, insulation resistance, partial discharge tests, dimensional conformity, and armor integrity assessment. All THCable products meet or exceed these standards.
Q4: Which installation standards must be followed?
A: Installations should adhere to IEC 60364, national electrical codes (e.g., NEC, BS7671), focusing on bending radius, minimum burial depth, and ampacity rating for safe operation.
Q5: What armouring type is adopted, and what are its benefits?
A: Double galvanized steel tape armoring as per VDE 0276/IEC 60502, providing mechanical strength, impact resistance, and electromagnetic interference shielding.
Q6: Can the cable be customized for halogen-free, low-smoke requirements?
A: Yes, outer sheath can be specified as LSZH (Low Smoke Zero Halogen) in compliance with IEC 60754/IEC 60332 for public, tunnel, or underground applications.
Q7: What's the expected service life and maintenance interval?
A: Typical service life is over 30 years with routine inspection intervals of 5-7 years, subject to site conditions and operational load, as per IEC/ISO recommendations.

Delivery Timeline, Warranty Commitment & After-sales Support

  • Production Lead Time: Standard specifications: 10 to 15 working days for N2XSEYBY/NA2XSEYBY 3.6/6kV 6/10kV 8.7/15kV 12/20kV MEDIUM VOLTAGE Cu CONDUCTOR XLPE INSULATED MULTI-CORE STEEL TAPE ARMOURED CABLE, custom variants: 20 working days.
  • Warranty: 36 months product warranty including free replacement for manufacturing defects.
  • Customer Support: Lifetime technical backup, complete document provision (type test report, RoHS declaration, certificate of origin), and on-site technical support for large projects.
  • Quality Assurance: Each batch monitored with batch code and full QA/QC traceability, referencing ISO 9001 and IEC 60502 procedures.

References & Authoritative Industry Links

Authoritative sources referenced above include IMARC, IEC, IEEE PES, ResearchGate, and real-world technology forum data. For further technical consultation, please contact the THCable engineering support team.


Share

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.