PVC FLAT 2 CORES | ||||||
Cross section (mm2) | Type of conductor | Nom.insulation thick.(mm) | Nom.outer sheath thick.(mm) | Earth cond.sect(mm2) | Nom.over.diam. | Approx.weight(kg/100m) |
1 | Solid copper | 0.6 | 0.9 | / | 6.5×4.2 | 5.00 |
1.5 | Stranded copper | 0.6 | 0.9 | / | 7.2×4.5 | 6.20 |
2.5 | Stranded copper | 0.7 | 1.0 | / | 8.9×5.4 | 9.70 |
4 | Stranded copper | 0.8 | 1.1 | / | 10.5×6.3 | 14.00 |
6 | Stranded copper | 0.8 | 1.1 | / | 11.6×6.9 | 19.00 |
10 | Stranded copper | 1.0 | 1.2 | / | 14.2×8.3 | 29.00 |
16 | Stranded copper | 1.0 | 1.3 | / | 16.3×9.5 | 42.00 |
PVC FLAT 3 CORES | ||||||
Cross section (mm2) | Type of conductor | Nom.insulation thick.(mm) | Nom.outer sheath thick.(mm) | Earth cond.sect(mm2) | Nom.over.diam. | Approx.weight(kg/100m) |
1.5 | Stranded copper | 0.6 | 0.9 | / | 9.9×4.5 | 8.80 |
PVC FLAT 3 CORES +EARTH | ||||||
Cross section (mm2) | Type of conductor | Nom.insulation thick.(mm) | Nom.outer sheath thick.(mm) | Earth cond.sect(mm2) | Nom.over.diam. | Approx.weight(kg/100m) |
1 | Solid copper | 0.6 | 0.9 | 1 | 8.9×4.2 | 7.74 |
1.5 | Stranded copper | 0.6 | 0.9 | 1.5 | 9.9×4.5 | 8.86 |
2.5 | Stranded copper | 0.7 | 1.0 | 2.5 | 12.2×5.4 | 14.03 |
4 | Stranded copper | 0.8 | 1.1 | 2.5 | 13.9×6.3 | 18.65 |
6 | Stranded copper | 0.8 | 1.1 | 2.5 | 15.0×6.9 | 23.04 |
10 | Stranded copper | 1.0 | 1.2 | 4 | 18.3×8.3 | 36.05 |
16 | Stranded copper | 1.0 | 1.3 | 6 | 21.0×9.5 | 51.46 |
PVC FLAT 3 CORES +EARTH |
||||||
Cross section (mm2) | Type of conductor | Nom.insulation thick.(mm) | Nom.outer sheath thick.(mm) | Earth cond.sect(mm2) | Nom.over.diam. | Approx.weight(kg/100m) |
1.5 | Stranded copper | 0.6 | 0.9 | 1.5 | 12.6×4.5 | 11.54 |
2.5 | Stranded copper | 0.7 | 1 | 2.5 | 15.7×5.4 | 18.31 |
Estrikti kab
Conductor material :copper
Conductor shape: Circular
Insulation: V-90
Outer Sheath: PVC
Deziyasyon kòd
TPS Cable
Aplikasyon
Flat TPS is more common than circular, and is used for fixed wiring of domestic and industrial lighting, power outlets, appliances, and HVAC units. Circular TPS is common in industrial and commercial installations but generally not in domestic installations.
Estanda
IAS/NZS 1125; AS/NZS 5000.2
2&3 core flat,
450/750V V-90 insulated,
PVC sheathed to AS/NZS 5000.2,
Copper conductors,90℃.
Lòt estanda tankou BS, DIN ak ICEA sou demann
Done teknik
Rated vòltaj: 450/750V
Bending factor when installed:4(×D)
Bending factor when laying:6(×D)
Sètifika
CE, RoHS, CCC, KEMA ak plis lòt moun sou demann
Detay anbalaj
Se kab apwovizyone, ak bobin an bwa, tanbou an bwa, tanbou an bwa asye ak bobin, oswa kòm kondisyon ou.
Tèt kab yo sele ak tep adezif BOPP ak bouchon sele ki pa igroskopik pou pwoteje pwent kab yo kont imidite. Yo dwe enprime mak ki nesesè yo ak yon materyèl ki reziste move tan sou deyò tanbou selon kondisyon kliyan an.
Tan livrezon
Nòmalman nan 7-14 jou (depann sou kantite lòd). Nou kapab satisfè orè livrezon ki pi strik yo dapre lòd pou achte. Respekte dat limit la se toujou pi gwo priyorite paske nenpòt reta nan livrezon kab la ka kontribiye nan reta pwojè an jeneral ak depans depase.
Port anbakman
Tianjin, Qingdao, oswa lòt pò selon kondisyon ou yo.
Kago lanmè
FOB/C&F/CIF sitasyon yo tout disponib.
Sèvis ki disponib
Echantiyon prèv yo dapre pwodiksyon ou oswa konsepsyon Layout.
Reponn ankèt nan lespas 12 èdtan, imèl reponn nan yon èdtan.
Lavant ki byen antrene ak ki gen eksperyans sou apèl.
Ekip rechèch ak devlopman yo disponib.
Pwojè Customized yo trè akeyi.
Dapre detay lòd ou yo, pwodiksyon ka ranje pou satisfè liy pwodiksyon an.
Rapò enspeksyon anvan chajman ka soumèt pa depatman QC nou an, oswa dapre twazyèm pati ou nonmen.
Bon sèvis apre-sale.