• Thús
  • Products
  • CONTROL CABLE
  • YSLYCY 0.6/1kV Cu Conductors with PVC Insulated and Sheathed,and Tinned Copper Wire Braided Screening Control Cable

YSLYCY 0.6/1kV Cu Conductors with PVC Insulated and Sheathed,and Tinned Copper Wire Braided Screening Control Cable

Cu Conductors with PVC Insulated and Sheathed,and Tinned Copper Wire Braided Screening Control Cable

Model Number: YSLYCY 0.6/1kV Control Cable
Kategory: Control Kabel
Plak fan oarsprong: XingTai, Sina
Merknamme: TIANHUAN
Certification ISO,CE,IEC,TUV

Minimum order quantity:5000 meters





DOWNLOAD PDF
Details
Tags

Parameter

Nom.Cross-section Area overall diameter cable Weight DC Resistance at 20℃ Conductor min
mm² mm km/kg Ω/km
3×1 11.2 196 19.5
3×1,5 10.9 187 13.3
3×2,5 13.5 326 7.98
3x4 15.1 391 4.95
4×0,75 11.4 214 26
4×1 11.8 231 19.5
4×1,5 12.2 265 13.3
4×2,5 14.6 379 7.98
4x4 16.7 557 4.95
4x6 18.7 723 3.3
4x10 21.9 1267 1.91
4x16 26.4 1763 1.21
4x25 32.5 2750 0.78
4×35 35.7 3497 0.554
4x50 41.1 4937 0.386
4x70 48 7480 0.272
4x95 51.2 10220 0.206
5×0,75 12.1 250 26
5×1 12.6 270 19.5
5×1,5 13.3 289 13.3
Nom.Cross-section Area overall diameter cable Weight DC Resistance at 20℃ Conductor min
mm² mm km/kg Ω/km
5x4 18.6 695 4.95
5x6 20.7 984 3.3
5x10 24.1 1635 1.91
5x16 28.8 2720 1.21
5x25 35.7 3490 0.78
7×0,75 13 319 26
7×1 14.5 289 19.5
7×1,5 16 416 13.3
7×2,5 17.9 590 7.98
12×0,75 15.8 437 26
12×1 17.4 493 19.5
12×1,5 19.6 641 13.3
12×2,5 21.9 897 7.98
18×0.75 18 588 26
18×1 20.7 658 19.5
18×1.5 23.4 872 13.3
18×2.5 26.1 1355 7.98
25×0.75 22.8 746 26
25×1 24.8 870 19.5
25×1.5 28.2 1211 13.3
25×2.5 31.9 1995 7.98

                                       

Kabel Struktuer

● Conductor:Class 5 flexible stranded bare copper

● Insulation:PVC

● Bedding PVC

● Screen:TinnedCopperBraided 70%Coverage

● Sheah:Special PVC-Compound

Koade oantsjutting

YSLYCY

Oanfraach

Flexible power,process control and instrumentation cable for industry,machinery and outdoor environment.The YSLYCY cable is resistant against most usual chemicals,oil and grease.This cable is suitable for indoor and outdoor application.

Standert

Europeanstandard :VDE 0482-332-1-2,EN 60881-404

Fire Retardantaccording to IEC/EN 60332-1-2

Other standardssuch as IEC,BS,DIN and ICEAuponrequest

Technyske data

Voltage Rating Uo/U:0.6/1kV

Temperature Rating:Fixed:-20℃ to +70℃

            Installation:-5℃ to+70℃

Minimum Bending Radius Fixed:5×overalldiameter

                                   Flexed:10×overall diameter

Sertifikaten

CE, RoHS, CCC, KEMA en mear oaren op oanfraach

As jo ​​ynteressearre binne yn ús produkten, kinne jo kieze in ferlitte jo ynformaasje hjir, en wy sille yn kontakt mei jo koart.


Skriuw jo berjocht hjir en stjoer it nei ús

As jo ​​ynteressearre binne yn ús produkten, kinne jo kieze in ferlitte jo ynformaasje hjir, en wy sille yn kontakt mei jo koart.