Parameter
Type: NGA(BTLY) Specification: 1×10-1×500mm² Nennspannung: 0,6/1 kV | ||||||||
Tabelle 1 | ||||||||
Kern × Fläche (mm²) |
Dirigent Durchmesser (mm) |
Isolierung Dicke (mm) |
Dicke aus Aluminium Legierungssatz (mm) |
Ca Durchmesser (mm) |
Ca Gewicht (kg/km) |
Dirigent Widerstand Ω/km |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und einlegen die Luft 40℃) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und Boden Temperatur von 25℃) |
1×10 | 4.0 | 0.7 | 1.4 | 20.6 | 536.2 | 1.83 | 71 | 92 |
1×16 | 5.0 | 0.7 | 1.4 | 21.7 | 626.1 | 1.15 | 92 | 115 |
1×25 | 6.0 | 0.9 | 1.4 | 23.2 | 779.8 | 0.727 | 120 | 150 |
1×35 | 7.0 | 0.9 | 1.4 | 24.3 | 922.5 | 0.524 | 150 | 180 |
1×50 | 8.2 | 1.0 | 1.4 | 25.7 | 1088.6 | 0.387 | 180 | 215 |
1×70 | 9.9 | 1.1 | 1.4 | 27.9 | 1259.5 | 0.268 | 230 | 265 |
1×95 | 11.6 | 1.1 | 1.5 | 29.8 | 1498.6 | 0.193 | 285 | 320 |
1×120 | 13.0 | 1.2 | 1.5 | 31.6 | 1762.5 | 0.153 | 335 | 360 |
1×150 | 14.5 | 1.2 | 1.6 | 33.6 | 2109.3 | 0.124 | 385 | 410 |
1×185 | 16.2 | 1.3 | 1.6 | 35.9 | 2585.7 | 0.0991 | 450 | 460 |
1×240 | 18.4 | 1.3 | 1.7 | 38.8 | 3255.6 | 0.0754 | 535 | 535 |
1×300 | 20.7 | 1.3 | 1.8 | 40.6 | 3987.4 | 0.0601 | 620 | 605 |
Type: NGA(BTLY) Specification: 2×1.5-2×400mm² Nennspannung: 0,6/1 kV | ||||||||
Tabelle 2 | ||||||||
Kern × Fläche (mm²) |
Dirigent Durchmesser (mm) |
Isolierung Dicke (mm) |
Dicke aus Aluminium Legierungssatz (mm) |
Ca Durchmesser (mm) |
Ca Gewicht (kg/km) |
Dirigent Widerstand (Ω/km) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und einlegen die Luft 40℃) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und Boden Temperatur von 25℃) |
2×2,5 | 1.76 | 0.7 | 1.4 | 22.7 | 589.8 | 7.41 | 28 | 39 |
2×4 | 2.23 | 0.7 | 1.4 | 23.9 | 637.7 | 4.61 | 37 | 51 |
2×6 | 2.74 | 0.7 | 1.4 | 25.5 | 735.1 | 3.08 | 47 | 64 |
2×10 | 4.0 | 0.9 | 1.4 | 26.8 | 812.4 | 1.83 | 65 | 86 |
2×16 | 5.0 | 0.9 | 1.4 | 28.3 | 985.3 | 1.15 | 84 | 110 |
2×25 | 6.0 | 1.0 | 1.4 | 34.6 | 1106.5 | 0.727 | 110 | 140 |
2×35 | 7.0 | 1.1 | 1.5 | 35.8 | 1756.3 | 0.524 | 135 | 170 |
2×50 | 8.2 | 1.1 | 1.5 | 38.8 | 2012.6 | 0.387 | 170 | 205 |
2×70 | 9.9 | 1.1 | 1.6 | 42.2 | 2436.8 | 0.268 | 215 | 250 |
2×95 | 11.6 | 1.2 | 1.6 | 46.0 | 3098.6 | 0.193 | 265 | 300 |
2×120 | 13.0 | 1.2 | 1.6 | 49.1 | 3946.5 | 0.153 | 310 | 345 |
2×150 | 14.5 | 1.2 | 1.6 | 54.4 | 4589.3 | 0.124 | 350 | 385 |
2×185 | 16.2 | 1.3 | 1.8 | 59.4 | 5521.7 | 0.0991 | 405 | 435 |
2×240 | 18.4 | 1.3 | 1.8 | 64.8 | 6785.1 | 0.0754 | 480 | 500 |
2×300 | 20.7 | 1.3 | 1.8 | 68.1 | 8438.9 | 0.0601 | 555 | 565 |
Typ: NGA (BTLY) Spezifikation: 3×1,5-3×400 mm² Nennspannung: 0,6/1 kV | ||||||||
Tisch 3 | ||||||||
Kern × Fläche (mm²) |
Dirigent Durchmesser (mm) |
Isolierung Dicke (mm) |
Dicke aus Aluminium Legierungssatz (mm) |
Ca Durchmesser (mm) |
Ca Gewicht (kg/km) |
Dirigent Widerstand (Ω/km) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und einlegen die Luft 40℃) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und Boden Temperatur von 25℃) |
3×2,5 | 1.76 | 0.7 | 1.4 | 26.5 | 683.5 | 7.41 | 28 | 39 |
3×4 | 2.23 | 0.7 | 1.4 | 27.9 | 812.1 | 4.61 | 37 | 51 |
3×6 | 2.74 | 0.7 | 1.4 | 29.3 | 930.2 | 3.08 | 47 | 64 |
3×10 | 4.0 | 0.9 | 1.4 | 30.4 | 1083.3 | 1.83 | 65 | 86 |
3×16 | 5.0 | 0.9 | 1.4 | 32.9 | 1359.6 | 1.15 | 84 | 110 |
3×25 | 6.0 | 1.0 | 1.4 | 33.8 | 2019.4 | 0.727 | 110 | 140 |
3×35 | 7.0 | 1.1 | 1.5 | 36.2 | 2511.2 | 0.524 | 135 | 170 |
3×50 | 8.2 | 1.1 | 1.5 | 39.8 | 3088.3 | 0.387 | 170 | 205 |
3×70 | 9.9 | 1.1 | 1.6 | 44.8 | 3954.6 | 0.268 | 215 | 250 |
3×95 | 11.6 | 1.2 | 1.6 | 48.7 | 4866.5 | 0.193 | 265 | 300 |
3×120 | 13.0 | 1.2 | 1.6 | 53.4 | 5798.3 | 0.153 | 310 | 345 |
3×150 | 14.5 | 1.2 | 1.6 | 58.2 | 6936.4 | 0.124 | 350 | 385 |
3×185 | 16.2 | 1.3 | 1.8 | 63.7 | 7832.6 | 0.0991 | 405 | 435 |
3×240 | 18.4 | 1.3 | 1.8 | 69.7 | 9155.8 | 0.0754 | 480 | 500 |
3×300 | 20.7 | 1.3 | 1.8 | 72.6 | 11264.2 | 0.0601 | 555 | 565 |
Typ: NGA (BTLY) Spezifikation: 4×1,5-4×400 mm² Nennspannung: 0,6/1 kV | ||||||||
Tabelle 4 | ||||||||
Kern × Fläche (mm²) |
Dirigent Durchmesser (mm) |
Isolierung Dicke (mm) |
Dicke aus Aluminium Legierungssatz (mm) |
Ca Durchmesser (mm) |
Ca Gewicht (kg/km) |
Dirigent Widerstand (Ω/km) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und einlegen die Luft 40℃) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und Boden Temperatur von 25℃) |
4×2,5 | 1.76 | 0.7 | 1.4 | 27.9 | 694.4 | 7.41 | 28 | 39 |
4x4 | 2.23 | 0.7 | 1.4 | 29.3 | 773.1 | 4.61 | 37 | 51 |
4×6 | 2.74 | 0.7 | 1.4 | 30.4 | 929.3 | 3.08 | 47 | 64 |
4×10 | 4.0 | 0.9 | 1.4 | 32.9 | 1280 | 1.83 | 65 | 86 |
4×16 | 5.0 | 0.9 | 1.4 | 33.8 | 1687 | 1.15 | 84 | 110 |
4×25 | 6.0 | 1.0 | 1.4 | 36.2 | 2326.4 | 0.727 | 110 | 140 |
4×35 | 7.0 | 1.1 | 1.5 | 39.8 | 2937.9 | 0.524 | 135 | 170 |
4×50 | 8.2 | 1.1 | 1.5 | 44.8 | 3808.3 | 0.387 | 170 | 205 |
4×70 | 9.9 | 1.1 | 1.6 | 48.7 | 5205.2 | 0.268 | 215 | 250 |
4×95 | 11.6 | 1.2 | 1.6 | 53.4 | 6748.7 | 0.193 | 265 | 300 |
4×120 | 13.0 | 1.2 | 1.6 | 58.2 | 8225.6 | 0.153 | 310 | 345 |
4×150 | 14.5 | 1.2 | 1.6 | 63.7 | 9115.6 | 0.124 | 350 | 385 |
4×185 | 16.2 | 1.3 | 1.8 | 69.7 | 10076.2 | 0.0991 | 405 | 435 |
4×240 | 18.4 | 1.3 | 1.8 | 72.6 | 11717.4 | 0.0754 | 480 | 500 |
4×300 | 20.7 | 1.3 | 1.8 | 81.2 | 14444.8 | 0.0601 | 555 | 565 |
Typ: NGA (BTLY) Spezifikation: 5×1,5-5×400 mm² Nennspannung: 0,6/1 kV | ||||||||
Tabelle 5 | ||||||||
Kern × Fläche (mm²) |
Dirigent Durchmesser (mm) |
Isolierung Dicke (mm) |
Dicke aus Aluminium Legierungssatz (mm) |
Ca Durchmesser (mm) |
Ca Gewicht (kg/km) |
Dirigent Widerstand (Ω/km) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und einlegen die Luft 40℃) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und Boden Temperatur von 25℃) |
5×2,5 | 1.76 | 0.7 | 1.4 | 30.0 | 856.4 | 7.41 | 28 | 39 |
5×4 | 2.23 | 0.7 | 1.4 | 33.2 | 929.3 | 4.61 | 37 | 51 |
5×6 | 2.74 | 0.7 | 1.4 | 35.0 | 1145.6 | 3.08 | 47 | 64 |
5×10 | 4.0 | 0.9 | 1.4 | 38.4 | 1549.1 | 1.83 | 65 | 86 |
5×16 | 5.0 | 0.9 | 1.4 | 42.6 | 1983.7 | 1.15 | 84 | 110 |
5×25 | 6.0 | 1.0 | 1.4 | 47.0 | 2937.9 | 0.727 | 110 | 140 |
5×35 | 7.0 | 1.1 | 1.5 | 51.2 | 3808.3 | 0.524 | 135 | 170 |
5×50 | 8.20 | 1.1 | 1.5 | 54.9 | 4608.6 | 0.387 | 170 | 205 |
5×70 | 9.90 | 1.1 | 1.6 | 60.1 | 5955.1 | 0.268 | 215 | 250 |
5×95 | 11.6 | 1.2 | 1.6 | 65.8 | 7269.2 | 0.193 | 265 | 300 |
5×120 | 13.0 | 1.2 | 1.6 | 68.6 | 8225.6 | 0.153 | 310 | 345 |
5×150 | 14.5 | 1.2 | 1.6 | 71.6 | 10076.2 | 0.124 | 350 | 385 |
5×185 | 16.2 | 1.3 | 1.8 | 75.9 | 12482.6 | 0.0991 | 405 | 435 |
5×240 | 18.4 | 1.3 | 1.8 | 76.5 | 15793.9 | 0.0754 | 480 | 500 |
5×300 | 20.7 | 1.3 | 1.8 | 83.7 | 19455.1 | 0.0601 | 555 | 565 |
Typ: NGA (BTLY) Spezifikation: 3×4+1×2,5-3×400+1×185mm² Nennspannung: 0,6/1 kV | ||||||||||
Tabelle 6 | ||||||||||
Kern × Fläche (mm²) |
Dirigent Durchmesser (mm) |
Isolierung Dicke (mm) |
Dicke aus Aluminium Legierungssatz (mm) |
Ca Durchmesser (mm) |
Ca Gewicht (kg/km) |
Dirigent Widerstand (Ω/km) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und einlegen die Luft 40℃) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und Boden Temperatur von 25℃) |
||
Phase | Neutral | Phase | Neutral | |||||||
3×4+1×2,5 | 2.23 | 1.76 | 0.7 | 0.7 | 1.4 | 29.2 | 868.4 | 4.61 | 37 | 51 |
3×6+1×4 | 2.74 | 2.23 | 0.7 | 0.7 | 1.4 | 30.5 | 987.3 | 3.08 | 47 | 64 |
3×10+1×6 | 4.0 | 2.74 | 0.7 | 0.7 | 1.4 | 32.9 | 1126.3 | 1.83 | 65 | 86 |
3×16+1×10 | 5.0 | 4.0 | 0.7 | 0.7 | 1.4 | 34.8 | 1498.2 | 1.15 | 84 | 110 |
3×25+1×16 | 6.0 | 5.0 | 0.9 | 0.7 | 1.4 | 41.5 | 2468.7 | 0.727 | 110 | 140 |
3×35+1×16 | 7.0 | 5.0 | 0.9 | 0.7 | 1.4 | 43.6 | 2796.5 | 0.524 | 135 | 170 |
3×50+1×25 | 8.2 | 6.0 | 1.0 | 0.9 | 1.5 | 45.8 | 3469.1 | 0.387 | 170 | 205 |
3×70+1×35 | 9.9 | 7.0 | 1.1 | 0.9 | 1.5 | 49.6 | 4398.2 | 0.268 | 215 | 250 |
3×95+1×50 | 11.6 | 8.2 | 1.1 | 1.0 | 1.6 | 52.7 | 5477.3 | 0.193 | 265 | 300 |
3×120+1×70 | 13.0 | 9.9 | 1.2 | 1.1 | 1.6 | 57.6 | 6781.9 | 0.153 | 310 | 345 |
3×150+1×70 | 14.5 | 9.9 | 1.4 | 1.1 | 1.6 | 61.2 | 7988.4 | 0.124 | 350 | 385 |
3×185+1×95 | 16.2 | 11.6 | 1.6 | 1.1 | 1.8 | 64.9 | 9654.2 | 0.0991 | 405 | 435 |
3×240+1×120 | 18.4 | 13.0 | 1.7 | 1.2 | 1.8 | 69.4 | 11386.1 | 0.0754 | 480 | 500 |
3×300+1×150 | 20.7 | 14.5 | 1.8 | 1.4 | 1.8 | 75.8 | 13125.6 | 0.0601 | 555 | 565 |
Typ: NGA (BTLY) Spezifikation: 3×4+2×2,5-3×400+2×185mm² Nennspannung:0,6/1KV | ||||||||||
Tabelle 7 | ||||||||||
Kern × Fläche (mm²) |
Dirigent Durchmesser (mm) |
Isolierung Dicke (mm) |
Mantel Dicke (mm) |
Ca Durchmesser (mm) |
Ca Gewicht (kg/km) |
Dirigent Widerstand (Ω/km) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und einlegen die Luft 40℃) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und Boden Temperatur von 25℃) |
||
Phase | Neutral | Phase | Neutral | |||||||
3×4+2×2,5 | 2.23 | 1.76 | 0.7 | 0.7 | 1.4 | 31.2 | 917.2 | 4.61 | 37 | 51 |
3×6+2×4 | 2.74 | 2.23 | 0.7 | 0.7 | 1.4 | 32.3 | 1036.2 | 3.08 | 47 | 64 |
3×10+2×6 | 4.0 | 2.74 | 0.7 | 0.7 | 1.4 | 34.6 | 1321.6 | 1.83 | 65 | 86 |
3×16+2×10 | 5.0 | 4.0 | 0.7 | 0.7 | 1.4 | 36.1 | 1688.2 | 1.15 | 84 | 110 |
3×25+2×16 | 6.0 | 5.0 | 0.9 | 0.7 | 1.4 | 43.2 | 3102.4 | 0.727 | 110 | 140 |
3×35+2×16 | 7.0 | 5.0 | 0.9 | 0.7 | 1.4 | 44.8 | 3516.2 | 0.524 | 135 | 170 |
3×50+2×25 | 8.2 | 6.0 | 1.0 | 0.9 | 1.5 | 47.5 | 4328.5 | 0.387 | 170 | 205 |
3×70+2×35 | 9.9 | 7.0 | 1.1 | 0.9 | 1.5 | 50.4 | 5436.9 | 0.268 | 215 | 250 |
3×95+2×50 | 11.6 | 8.2 | 1.1 | 1.0 | 1.6 | 55.2 | 6784.7 | 0.193 | 265 | 300 |
3×120+2×70 | 13.0 | 9.9 | 1.2 | 1.1 | 1.6 | 59.1 | 8213.6 | 0.153 | 310 | 345 |
3×150+2×70 | 14.5 | 9.9 | 1.4 | 1.1 | 1.6 | 64.8 | 9238.7 | 0.124 | 350 | 385 |
3×185+2×95 | 16.2 | 11.6 | 1.6 | 1.1 | 1.8 | 68.9 | 10254.7 | 0.0991 | 405 | 435 |
3×240+2×120 | 18.4 | 13.0 | 1.7 | 1.2 | 1.8 | 74.5 | 13689.4 | 0.0754 | 480 | 500 |
3×300+2×150 | 20.7 | 14.5 | 1.8 | 1.4 | 1.8 | 80.1 | 16527.8 | 0.0601 | 555 | 565 |
Typ: NGA(BTLY) Spezifikation: 4×4+1×2,5-4×400+1×185mm² Nennspannung: 0,6/1 kV | ||||||||||
Tabelle 8 | ||||||||||
Kern × Fläche (mm²) |
Dirigent Durchmesser (mm) |
Isolierung Dicke (mm) |
Mantel Dicke (mm) |
Ca Durchmesser (mm) |
Ca Gewicht (kg/km) |
Dirigent Widerstand (Ω/km) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und einlegen die Luft 40℃) |
Tragen Kapazität A (Arbeiten Temperatur 90℃ und Boden Temperatur von 25℃) |
||
Phase | Neutral | Phase | Neutral | |||||||
4×4+1×2,5 | 2.23 | 1.76 | 0.7 | 0.7 | 1.8 | 30.8 | 971.2 | 4.61 | 37 | 51 |
4×6+1×4 | 2.74 | 2.23 | 0.7 | 0.7 | 1.8 | 31.7 | 1039.1 | 3.08 | 47 | 64 |
4×10+1×6 | 4.0 | 2.74 | 0.7 | 0.7 | 1.8 | 33.9 | 1354.1 | 1.83 | 65 | 86 |
4×16+1×10 | 5.0 | 4.0 | 0.7 | 0.7 | 1.8 | 36.1 | 1809.2 | 1.15 | 84 | 110 |
4×25+1×16 | 6.0 | 5.0 | 0.9 | 0.7 | 1.8 | 42.6 | 2440.1 | 0.727 | 110 | 140 |
4×35+1×16 | 7.0 | 5.0 | 0.9 | 0.7 | 1.8 | 45.1 | 2828.7 | 0.524 | 135 | 170 |
4×50+1×25 | 8.2 | 6.0 | 1.0 | 0.9 | 1.9 | 48.6 | 3730.2 | 0.387 | 170 | 205 |
4×70+1×35 | 9.9 | 7.0 | 1.1 | 0.9 | 2.1 | 52.9 | 4946.1 | 0.268 | 215 | 250 |
4×95+1×50 | 11.6 | 8.2 | 1.1 | 1.0 | 2.2 | 55.7 | 6382.6 | 0.193 | 265 | 300 |
4×120+1×70 | 13.0 | 9.9 | 1.2 | 1.1 | 2.4 | 60.8 | 8055.3 | 0.153 | 310 | 345 |
4×150+1×70 | 14.5 | 9.9 | 1.4 | 1.1 | 2.5 | 66.2 | 9238.7 | 0.124 | 350 | 385 |
4×185+1×95 | 16.2 | 11.6 | 1.6 | 1.1 | 2.7 | 70.5 | 11554.2 | 0.0991 | 405 | 435 |
4×240+1×120 | 18.4 | 13.0 | 1.7 | 1.2 | 2.9 | 76.8 | 14430.1 | 0.0754 | 480 | 500 |
4×300+1×150 | 20.7 | 14.5 | 1.8 | 1.4 | 3.1 | 81.2 | 17757.3 | 0.0601 | 555 | 565 |
Anwendung
MI-Kabel werden hauptsächlich für Hochtemperaturumgebungen oder sicherheitskritische Signal- und Stromversorgungssysteme verwendet. Es kann jedoch zusätzlich innerhalb eines Mietgebiets genutzt werden, wobei der Strom geliefert und dem Vermieter in Rechnung gestellt wird.
Kabelstruktur
1. Kupferleiter
2. Isolationsschicht
3. Feuerfeste Schicht
4. Isolierschicht
5.Aluminiumhülle
6. Raucharmer, halogenfreier Mantel
Anwendungen
Dieses Produkt eignet sich für Leitungen mit einer Nennspannung von 0,6/1 kV und darunter und wird häufig in Kernkraftwerken, der Metallurgie, der chemischen Industrie, Bergwerken, Öfen und anderen gefährlichen, rauen Umgebungen und Hochtemperaturumgebungen eingesetzt.
In den letzten Jahren wurde es auch in Hochhäusern, Flughäfen, Docks, U-Bahnen und anderen Orten eingesetzt, um den unterbrechungsfreien Betrieb von Feuerlöschpumpen, Feueraufzügen, lokaler Beleuchtung, Anweisungen zur Notfallevakuierung, Sicherheitsüberwachung, Rauchschutzsystemen usw. sicherzustellen Selbst bereitgestellte Stromversorgungen und sonstiger Brandschutzstrom sowie wichtige Geräte im Brandfall.
Produkteigenschaften
1) Beim Verlegen muss kein separates Rohr getragen werden und es verfügt über die gleichen wasserdichten und stoßfesten Funktionen wie BTT
2) Die maximale Nenntemperatur für Kabelleiter beträgt 125 °C
3) Das Produkt kann mit 1 bis 37 Adern in den Spezifikationen von 1,5 bis 6 mm², 1 bis 5 Adern in den Spezifikationen von 10 bis 240 mm² und Einzeladern in den Spezifikationen von 300 bis 630 mm² hergestellt werden
4) Das Kabel hat die drei Tests C, W und E gemäß BS6387 bestanden, wodurch die Integrität des Stromkreises während des Brandes aufrechterhalten werden kann
5) Gute Funktionen gegen Ratten, Ameisen und Strahlung, die die Stabilität, lange Lebensdauer und Haltbarkeit des Kabels gewährleisten können
6) Niedrige Betriebstemperatur, geringer Leitungsverlust, starke Überlastschutzfähigkeit, lange Lebensdauer und hohe Sicherheit, besonders geeignet für Anwendungen in Projekten mit Umweltschutzanforderungen
7) Korrosionsbeständig (der Metallmantel des mineralisolierten Kabels des BTLY-Modells ist äußerst korrosionsbeständig und erfordert bei den meisten Installationen keine zusätzlichen Schutzmaßnahmen; selbst an Orten, an denen der Metallmantel des Kabels anfällig für chemische Korrosion oder schwer ist Auch vor industrieller Kontamination bleibt es sicher, da die äußerste Schicht des Kabels durch einen Außenmantel aus Kunststoff geschützt ist.
8) Explosionsgeschützt (das hochverdichtete Isoliermaterial im Kabel und der mit einer speziellen Kabelverschraubung installierte Kabelabschluss können verhindern, dass Dampf, Gas und Flammen in die an das Kabel angeschlossenen elektrischen Geräte eindringen, sodass es an explosionsgefährdeten Orten verwendet werden kann der Anschluss verschiedener explosionsgeschützter Geräte und Anlagen.
9) Hohe mechanische Festigkeit (mineralisoliertes BTLY-Kabel ist robust und langlebig und kann auch dann noch normal funktionieren, wenn der Kabeldurchmesser um ein Drittel verformt wird; seine elektrischen Eigenschaften werden auch bei schwerer mechanischer Beschädigung nicht beeinträchtigt.