The Type
The Type
MYJV42  Coal Mine Used XLPE Insulated Coarse Steel Wire Armored PVC Sheathed Power Cable

MYJV42 Coal Mine Used XLPE Insulated Coarse Steel Wire Armored PVC Sheathed Power Cable

CABLE STRUCTURE:

Conductor:Copper

Insulation:XLPE

Inner sheath:PVC

Armor layer:Coarse steel wire armoring

outer sheath:PVC


Technical Data

TECHNICAL DATA:

Rated voltage:(U₀/U)0.6/1 kV;(U₀/U)8.7/10kV

Temperature classification:The cable conductor is permitted to have a maximum long-term operating temperature not exceeding 90℃.During a short circuit(with the maximum duration not exceeding 5 seconds),the maximum temperature of the cable conductor does not exceed 250℃.When laying the cables on the ground,the ambient temperature during the laying process should not be lower than 0℃.

Min.Bending Radius:3 core:12(D+d)±5%

Finished product voltage test:Wire core:3.5kV/5minutes

Installation scenario:It can be used in indoor environments,tunnels,cable trenches,or underground direct burial,in damp environments and areas with high groundwater levels.It can withstand certain mechanical external forces and certain tensile forces.Indoor,tunnels,cable trenches,shafts or underground direct burial,etc.,can withstand mechanical external forces and certain tensile forces.

MYJV42  0.6/1kV

Nominal cross-
section
Conductor
diameter
Insulation
thickness
Inner sheath
thickness
 Number   of
armored steel
    wires
The diameter of
armored  steel
    wire
Outer sheath
 thickness
Maximum    direct
current resistance
of the conductor at
20℃
mm2mmmmmm
mmmmΩ/km
3×507.6 1.0 2.0 21 4.0 2.1 0.3870 
3×709.2 1.1 2.0 24 4.0 2.2 0.2680 
3×9510.8 1.1 2.0 27 4.0 2.3 0.1930 
3×12012.2 1.2 2.0 29 4.0 2.4 0.1530 
3×15013.6 1.4 2.0 32 4.0 2.6 0.1240 
3×18515.1 1.6 2.0 35 4.0 2.7 0.0991 
3×24017.3 1.7 2.0 39 4.0 2.9 0.0754 
3×30019.4 1.8 2.0 43 4.0 3.1 0.0601 

MYJV42  8.7/10kV



Nominal cross-
section


Conductor
diameter


Insulation nominal Nominal thickness
thickness      of the sheath


Outer diameter of
the cable
Cable weightMaximum    direct
current resistance
of the conductor at
      20℃


25℃ cable current
carrying  capacity
mm2mmmm               mmmmkm/kgΩ/kmin ground(A)in air(A)
50 8.3 4.5             2.964.6 8122 0.387 206 212 
70 9.8 4.5              368.4 9247 0.268 251 264 
95 11.5 4.5             3.172.1 10500 0.193 298 320 
120 12.9 4.5             3.275.3 11624 0.153 336 365 
150 14.5 4.5             3.379 13024 0.124 375 415 
185 16 4.5             3.583.8 14758 0.0991 419 470 
240 18.3 4.5             3.788.7 16951 0.0754 479 549 


Application

Suitable for fixed installation in power distribution networks with rated voltage of 10kV or less,or in industrial installations.

The list of products in our website is continually being updated. Please send us an email if you have any questions about products that are not included yet.
Customized Service

At TianHuan Cable Group, we specialise in creating custom cables and harnesses for the world’s most demanding applications. Different materials are used according to customer requirements to meet different weather resistance, application, safety levels, and environmental requirements.

Contact Us +